Results 311 to 320 of about 262,039 (330)
Some of the next articles are maybe not open access.
Current transformer calibration
1988The practical application of the current comparator to current transformer calibration is accomplished with a configuration that has been called the compensated current comparator. The principal feature of this configuration is a winding located inside the main magnetic shield which has the same number of turns as one of the ratio windings located ...
openaire +1 more source
Methods for Testing Current Transformers
Transactions of the American Institute of Electrical Engineers, 1924In the sale of electric power especially in large amounts at high voltages, current transformers are universally used to operate the meters from the readings of which the bills are made out. While the secondary currents of such transformers reproduce fairly faithifully on a smaller scale the conditions of current strength and phase existing in their ...
openaire +1 more source
Harmonics in transformer magnetizing currents
Proceedings of the American Institute of Electrical Engineers, 1915The purpose of this paper is to show in a concise manner the cause and effects of higher harmonic currents in magnetizing currents of transformers. A hypothetical case is analyzed to show the cause of the harmonics; then the schemes of connecting transformers that are commonly used for polyphase transformation are taken up and the effects of the ...
openaire +1 more source
Reviewing current transformers and current transducers
2007 Electrical Insulation Conference and Electrical Manufacturing Expo, 2007The purpose of this paper is to provide a tutorial review of three types of current transducers that are used in instruments and power. The three current transducers that will be discussed are; (1) the ac current transducer; (2) the dc current saturable reactor; and (3) the Hall effect generator with the rugged solid iron core.
openaire +1 more source
Current transformers near high-current busses
Electrical Engineering, 1951WHEN CURRENT TRANSFORMERS are applied in the vicinity of busses carrying large currents, the transformer accuracy may be very seriously affected. This is particularly true on systems which normally carry over 2,000 amperes and may carry 10 or 20 times this current during faults.
openaire +1 more source
Current Status of Bacterial Transformations
1955Publisher Summary When it became clear that a number of plant viruses are crystallizable macromolecules composed of ribonucleic acid and protein, it was possible to attribute to a particular sort of macromolecule the striking biological property of autoreproduction.
openaire +2 more sources
Low-Current-Secondary Current Transformers
Transactions of the American Institute of Electrical Engineers, 1946openaire +2 more sources
The Direct Current Transformer
1961Among numerous problems of cryogenic engineering there is the one of electrical conduction from an external room temperature source into a low temperature environment. For currents over a few amperes the problem is one of providing electrical conductors of suitable current carrying capacity without introducing excessive thermal conduction.
openaire +1 more source