Results 41 to 50 of about 76,902 (300)

Sirolimus for Extracranial Arteriovenous Malformations: A Scoping Review of the Evidence in Syndromic and Non‐Syndromic Cases

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Arteriovenous malformations (AVMs) are rare, high‐flow, vascular anomalies that can occur either sporadically or as part of a genetic syndrome. AVMs can progress with serious morbidity and even mortality if left unchecked. Sirolimus is an mTOR inhibitor that is effective in low‐flow vascular malformations; however, its role in AVMs is unclear.
Will Swansson   +3 more
wiley   +1 more source

Energy Curtailment Scheduling MILP Formulation for an Islanded Microgrid with High Penetration of Renewable Energy

open access: yesEnergies, 2021
The efficiency of photovoltaic (PV) cells has improved significantly in the last decade, making PV generation a common feature of the sustainable microgrid.
Woan-Ho Park   +3 more
doaj   +1 more source

Evaluating the Utility of Paired Tumor and Germline Targeted DNA Sequencing for Pediatric Oncology Patients: A Single Institution Report

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Objective To evaluate the diagnostic yield and utility of universal paired tumor–normal multigene panel sequencing in newly diagnosed pediatric solid and central nervous system (CNS) tumor patients and to compare the detection of germline pathogenic/likely pathogenic variants (PV/LPVs) against established clinical referral criteria for cancer ...
Natalie Waligorski   +9 more
wiley   +1 more source

Wind Resource Quality Affected by High Levels of Renewables

open access: yesResources, 2015
For solar photovoltaic (PV) and wind resources, the capacity factor is an important parameter describing the quality of the resource. As the share of variable renewable resources (such as PV and wind) on the electric system is increasing, so does ...
Victor Diakov
doaj   +1 more source

A virtual power plant model for time-driven power flow calculations [PDF]

open access: yes, 2017
This paper presents the implementation of a custom-made virtual power plant model in OpenDSS. The goal is to develop a model adequate for time-driven power flow calculations in distribution systems.
Guerra Sánchez, Luis Gerardo   +1 more
core   +2 more sources

Wind generator behaviour in a pay-as-bid curtailment market [PDF]

open access: yes, 2013
A pay-as-bid curtailment market, where Wind Power Plants (WPPs) may offer prices to have their output reduced in the event of network balancing or stability constraints, is one approach towards the market integration of a high proportion of wind energy ...
Bell, Keith, Hawker, Graeme, Kane, Laura
core  

Two Faces of NOTCH1 in Childhood Lymphoblastic T‐Cell Neoplasia: Prognostic Divergence of Mutational and Structural Aberrations

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT In pediatric patients, T‐cell lymphoblastic lymphoma (T‐LBL) survival exceeds 80%. Relapse remains associated with limited curative options. Frontline treatment is largely extrapolated from T‐cell acute lymphoblastic leukemia (T‐ALL) treatment, reflecting the ongoing debate, whether both entities represent distinct diseases or variants within ...
Marie C. Heider   +4 more
wiley   +1 more source

A Hybrid Energy Storage System and the Contribution to Energy Production Costs and Affordable Backup in the Event of a Supply Interruption—Technical and Financial Analysis

open access: yesEnergies
Alternative energies are essential for meeting the global demand for environmentally friendly energy, especially as the use of fossil fuels is being reduced.
Carlos Felgueiras   +9 more
doaj   +1 more source

Dietary Protein Intake and Peritoneal Protein Losses in Peritoneal Dialysis Patients

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Peritoneal dialysis (PD) patients lose protein in their waste dialysate, potentially increasing their risk for malnutrition. We wished to determine whether there was any association between losses and dietary protein intake (DPI). Methods DPI was assessed from 24‐h dietary recall using Nutrics software.
Haalah Shaaker, Andrew Davenport
wiley   +1 more source

An Optimized Combination of a Large Grid Connected PV System along with Battery Cells and a Diesel Generator [PDF]

open access: yes, 2016
Environmental, economical and technical benefits of photovoltaic (PV) systems make them to be used in many countries. The main characteristic of PV systems is the fluctuations of their output power.
Ferdowsi, Farzad   +2 more
core   +2 more sources

Home - About - Disclaimer - Privacy