Results 131 to 140 of about 733 (173)
Some of the next articles are maybe not open access.
Videodocumentation in digital dacryocystography
International Ophthalmology, 1991The digital dacryocystography proved to be the optimum method of X-ray diagnostics in obstructions of the lacrimal pathways. The examination was performed with a computer controlled X-ray unit with a C-arc coupled to an image intensifier tv-system. In the study the advantages of this technique were combined with the advantages of modern videotechnique.
E, Huber, F J, Steinkogler, F, Karnel
openaire +2 more sources
MR dacryocystography: comparison with dacryocystography and CT dacryocystography.
AJNR. American journal of neuroradiology, 2000Several techniques have been used to image the nasolacrimal system, providing functional (dacryoscintigraphy) or morphologic (dacryocystography, CT dacryocystography [CTD]) information. Using gadopentetate dimeglumine-diluted solution injected into the lacrimal canaliculus or instilled into the conjunctival sac, we compared the sensitivity of MR ...
L, Manfrè +5 more
openaire +1 more source
A Head-Holder for Radioriuclide Dacryocystography
Radiology, 1976Proper patient immobilization, essential for good-quality radionuclide studies of the lacrimal system, is achieved with a head-holder which is adjustable in both vertical and horizontal directions.
D R, Chenoweth, J J, Hurwitz
openaire +2 more sources
Technical report: Digital subtraction dacryocystography
Clinical Radiology, 1990Twenty-one patients presenting clinically with obstructive epiphora were investigated by digital subtraction dacryocystography (DSDCG). This technique is quick and simple to perform, with good patient acceptance. It produces diagnostic images on a single radiographic projection. The proximal lacrimal apparatus is well demonstrated.
S J, King, S F, Haigh
openaire +2 more sources
Klinische Monatsblatter fur Augenheilkunde, 1987
The technique of conventional dacryocystography has recently been improved and extended by utilizing new technological developments. Digital dacryocystography, performed with computer-controlled X-ray equipment with a C-arc, and coupled to an image intensifier-TV system, enables the passage of the contrast medium to be observed, the image to be ...
F J, Steinkogler +2 more
openaire +1 more source
The technique of conventional dacryocystography has recently been improved and extended by utilizing new technological developments. Digital dacryocystography, performed with computer-controlled X-ray equipment with a C-arc, and coupled to an image intensifier-TV system, enables the passage of the contrast medium to be observed, the image to be ...
F J, Steinkogler +2 more
openaire +1 more source
[Automatic injector in dacryocystography].
La Radiologia medica, 1989A new equipment is described for the radiologic examination of the lacrimal system. The technique has been so far employed with excellent results in a series of 75 patients with obstructive epiphora. The advantages of the automatic injector are emphasized: 1) only one person suffice to carry out the examination; 2) the operator is placed far from the ...
P, Ponte, A, Montanara
openaire +1 more source
Dacryocystography: CT or MRI ?
2018Aims and objectives: Epiphora is defined as overflow of tears caused by imperfect drainage of the tear-conducting passages (Fig. 1) and is a common ophthalmic problem, accounting for 3% of ambulatory clinic visits [1].
openaire +1 more source

