Results 131 to 140 of about 733 (173)
Some of the next articles are maybe not open access.

Videodocumentation in digital dacryocystography

International Ophthalmology, 1991
The digital dacryocystography proved to be the optimum method of X-ray diagnostics in obstructions of the lacrimal pathways. The examination was performed with a computer controlled X-ray unit with a C-arc coupled to an image intensifier tv-system. In the study the advantages of this technique were combined with the advantages of modern videotechnique.
E, Huber, F J, Steinkogler, F, Karnel
openaire   +2 more sources

MR dacryocystography: comparison with dacryocystography and CT dacryocystography.

AJNR. American journal of neuroradiology, 2000
Several techniques have been used to image the nasolacrimal system, providing functional (dacryoscintigraphy) or morphologic (dacryocystography, CT dacryocystography [CTD]) information. Using gadopentetate dimeglumine-diluted solution injected into the lacrimal canaliculus or instilled into the conjunctival sac, we compared the sensitivity of MR ...
L, Manfrè   +5 more
openaire   +1 more source

A Head-Holder for Radioriuclide Dacryocystography

Radiology, 1976
Proper patient immobilization, essential for good-quality radionuclide studies of the lacrimal system, is achieved with a head-holder which is adjustable in both vertical and horizontal directions.
D R, Chenoweth, J J, Hurwitz
openaire   +2 more sources

DACRYOCYSTOGRAPHY

Radiologic Clinics of North America, 1972
T H, Pettit, C G, Coin
openaire   +4 more sources

Technical report: Digital subtraction dacryocystography

Clinical Radiology, 1990
Twenty-one patients presenting clinically with obstructive epiphora were investigated by digital subtraction dacryocystography (DSDCG). This technique is quick and simple to perform, with good patient acceptance. It produces diagnostic images on a single radiographic projection. The proximal lacrimal apparatus is well demonstrated.
S J, King, S F, Haigh
openaire   +2 more sources

[Digital dacryocystography].

Klinische Monatsblatter fur Augenheilkunde, 1987
The technique of conventional dacryocystography has recently been improved and extended by utilizing new technological developments. Digital dacryocystography, performed with computer-controlled X-ray equipment with a C-arc, and coupled to an image intensifier-TV system, enables the passage of the contrast medium to be observed, the image to be ...
F J, Steinkogler   +2 more
openaire   +1 more source

Kinetic Dacryocystography

American Journal of Ophthalmology, 1970
S L, Trokel, G D, Potter
openaire   +2 more sources

[Automatic injector in dacryocystography].

La Radiologia medica, 1989
A new equipment is described for the radiologic examination of the lacrimal system. The technique has been so far employed with excellent results in a series of 75 patients with obstructive epiphora. The advantages of the automatic injector are emphasized: 1) only one person suffice to carry out the examination; 2) the operator is placed far from the ...
P, Ponte, A, Montanara
openaire   +1 more source

Dacryocystography: CT or MRI ?

2018
Aims and objectives: Epiphora is defined as overflow of tears caused by imperfect drainage of the tear-conducting passages (Fig. 1) and is a common ophthalmic problem, accounting for 3% of ambulatory clinic visits [1].
openaire   +1 more source