Results 241 to 250 of about 23,296,124 (362)

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

Alpha-synuclein seed amplification assays: Data sharing, standardization needed for clinical use. [PDF]

open access: yesSci Adv
Lashuel HA   +8 more
europepmc   +1 more source

BreastWatch: A Varian Eclipse script tool for Community‐Based automatic evaluation of breast treatment plans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli   +8 more
wiley   +1 more source

VRML data sharing in the spin-3D CVE

open access: green, 2002
Stéphane Louis Dit Picard   +3 more
openalex   +2 more sources

Data sharing ethics toolkit: The Human Cell Atlas. [PDF]

open access: yesNat Commun
Kirby E   +7 more
europepmc   +1 more source

An extension to the OVH concept for knowledge‐based dose volume histogram prediction in lung tumor volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Volumetric‐modulated arc therapy (VMAT) treatment planning allows a compromise between a sufficient coverage of the planning target volume (PTV) and a simultaneous sparing of organs‐at‐risk (OARs). Particularly in the case of lung tumors, deciding whether it is possible or worth spending more time on further improvements of a treatment
Johann Brand   +4 more
wiley   +1 more source

Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy