A Method for Detecting DC Bias in Transformer of Dual Active Bridge DC-DC Converter

open access: yes2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia), 2021
A potential concern with the isolation transformer in a dual active bridge DC-DC converter (DAB) unit is the DC bias of magnetization. With the influence of DC bias, the loss of the transformer increases, and the lifespan decreases. However, it is difficult to accurately measure the small DC component mixed in a large (>10A peak), high-frequency AC ...
Guanqun Qiu   +5 more
openaire   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

DC Bias Study for DC-DC Dual-Active-Bridge Converter

2018 IEEE 4th Southern Power Electronics Conference (SPEC), 2018
For the dual-active-bridge (DAB) converter, the adoption of high-frequency transformer provides galvanic isolation, but also brings the possibility of dc bias. In this paper, the calculation methods for dc bias are derived in details. Hence, the dc bias magnetizing current can be predicted considering the inconsistency of semiconductor switches and ...
Liangcai Shu   +5 more
openaire   +1 more source