Results 101 to 110 of about 1,916 (295)
Interfacial charge transfer and low‐resistance interphase formation between PEO‐based polymer and Li10GeP2S12 solid electrolytes are investigated using multi‐electrode impedance spectroscopy and advanced analytical techniques such as XPS and ToF‐SIMS.
Ujjawal Sigar +6 more
wiley +1 more source
Simplified quantum sensing technique for the detection of short electrical signals occurring in neuronal signaling or bioinspired technologies. We demonstrate a single frequency continuous‐wave optically detected magnetic resonance (CW‐ODMR) approach to sense signals that can be as short as 0.2 ms.
João Paulo Silva +4 more
wiley +1 more source
The use of advanced switching technologies, including hybrid and fully semiconductor-based circuit breakers, enables a significant reduction in the prospective short-circuit current. This enhances the level of circuit protection by minimizing thermal and
Łukasz Nowak +2 more
doaj +1 more source
Key stress extraction and equivalent test method for hybrid DC circuit breaker
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological ...
Chong Gao +4 more
doaj +1 more source
This review explores advances in wearable and lab‐on‐chip technologies for breast cancer detection. Covering tactile, thermal, ultrasound, microwave, electrical impedance tomography, electrochemical, microelectromechanical, and optical systems, it highlights innovations in flexible electronics, nanomaterials, and machine learning.
Neshika Wijewardhane +4 more
wiley +1 more source
Milled polycrystalline NMC811 cathode (MPC NMC) with smaller secondary particle and higher surface area had 1) greater cathode tortuosity, 2) reduced surface Ni on the cycled MPC cathodes consistent with surface reconstruction, and 3) increased Ni deposition from cathode‐anode crosstalk, manifesting in lower functional capacity and higher impedance ...
Edelmy J. Marin Bernardez +22 more
wiley +1 more source
Considering the voltage source characteristics of the converters in the flexible DC grid, the current-limiting reactors are usually placed on the DC line terminals to limit the fault current rising speed.
Yingqing Ma +5 more
doaj +1 more source
Model High-Speed DC Circuit Breaker
В. Сиченко: ORCID 0000-0002-9533-2897UK: В статті наведені принципи створення моделі вимикача постійного струму. Подані результати моделювання різних типів вимикачів постійного струму.RU: В статье приведены принципы создания модели выключателя ...
Сиченко, Віктор Григорович +2 more
core +1 more source
Reduced DC circuit breaker requirement on mixed converter HVDC networks [PDF]
Recently proposed meshed HVDC networks include both converters and DC circuit breakers, and the fault currents experienced and therefore the capacity requirement of circuit breakers are dependent on the topology of converters used on the network.
Green, TC +3 more
core +1 more source
Magnetic Droplet Manipulation on Open Surfaces
Recent advances in the manipulation of magnetic droplets demonstrate various manipulations on open surfaces, including transport, splitting, merging, and force‐controlled motion, enabled by magnetic particles and external fields. ABSTRACT Manipulation of liquids on a smaller scale enables applications in various fields, particularly diagnostics and ...
Robab Jahangir, Vahid Nasirimarekani
wiley +1 more source

