Investigations on the safe stroke of mechanical HVDC vacuum circuit breaker
Here, a DC vacuum arc interruption test based on the hybrid high-speed actuator and the method of commutation is carried out in the synthetic loop system. The safe stroke is one of the basic breaking parameters.
Ning Xia +5 more
doaj +1 more source
Multi-port DC circuit breaker based on dual capacitor current limiting and energy sink
The coupling relationship between the removal of the fault current and the dissipation of the residual energy of the fault line during the fault isolation process of the multi-port capacitive current-limiting DC circuit breaker prolongs the breaking time
Wei Gu +5 more
doaj +1 more source
A Current-Commutation DC Circuit Breaker with Adaptive Reclosing Capability [PDF]
DC faults are critical events in a flexible high-voltage dc (HVDC) grid. Thus, ensuring that the power system returns to normal operation rapidly and reliably after fault isolation is very important. This requires a HVDC breaker. In overhead line systems
Jiang Chunbing, Zhao Chengyong
doaj +1 more source
Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X +6 more
core +1 more source
DC interruption characteristic of vacuum circuit breaker
AbstractA high‐speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high‐frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the
Hiromi Odaka +5 more
openaire +2 more sources
A hybrid DC circuit breaker based on a generalized H-bridge circuit
Given the rapid development of multi-terminal DC power grids and the treatment of DC faults, a high-voltage hybrid DC circuit breaker based on a generalized H-bridge circuit is proposed.
LU Yi +6 more
doaj +1 more source
Optimizing the roles of unit and non-unit protection methods within DC microgrids [PDF]
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements.
Burt, Graeme +4 more
core +1 more source
A comprehensive review of impedance source network DC circuit breaker topologies
Dc microgrids (MG) have drawn more attention due to the demand for renewable energy sources, energy storage devices in distributed generation, and the separation of DC loads requiring more power converters.
Marwan R. Abed +3 more
semanticscholar +1 more source
Parameters design of voltage sharing components for the series multi‐break mechanical switch
Series multi‐break mechanical switch is one of the critical components of high‐voltage hybrid DC circuit breakers. However, due to the existence of distributed capacitance, the voltage distribution between the breaks is not balanced.
Daochun Huang +5 more
doaj +1 more source
Types of Circuit Breaker and its Application in Substation Protection [PDF]
Power system consists of the generation, transmission, distribution, and substation. All the power system component requires suitable protection devices as the protection system to protect the system during fault occur. In this paper, the circuit breaker
bin Hamzah, Nur Iskandar +6 more