Results 51 to 60 of about 1,494,632 (291)
Investigations on the safe stroke of mechanical HVDC vacuum circuit breaker
Here, a DC vacuum arc interruption test based on the hybrid high-speed actuator and the method of commutation is carried out in the synthetic loop system. The safe stroke is one of the basic breaking parameters.
Ning Xia +5 more
doaj +1 more source
Improving DC Circuit Breaker Performance Through an Alternate Commutating Circuit
Fault interruption in de circuits is more challenging than in their ac counterparts. The absence of natural current zero crossing along with resistive nature of the dc grids creates a significantly higher fault current to disrupt at the dc circuit ...
Sudipta Sen +5 more
core +1 more source
A DC circuit breaker for an electric vehicle battery pack [PDF]
Electric vehicle battery packs require DC circuit breakers for safety. These must break thousands of Amps DC at hundreds of Volts. The Sunshark solar racing car has a 140V 17Ahr battery box which needs such a breaker.
Walker, G. R., Walker, Geoffrey R.
core +1 more source
Shellac, a centuries‐old natural resin, is reimagined as a green material for flexible electronics. When combined with silver nanowires, shellac films deliver transparency, conductivity, and stability against humidity. These results position shellac as a sustainable alternative to synthetic polymers for transparent conductors in next‐generation ...
Rahaf Nafez Hussein +4 more
wiley +1 more source
DC interruption characteristic of vacuum circuit breaker
AbstractA high‐speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high‐frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the
Odaka, Hiromi +5 more
openaire +2 more sources
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Design of mine breaker with self-diagnosis function
Aim at the problem that a coal mine safety monitoring system cannot accurately sense the power-off state of a controlled object due to the fact that the output wire of a mine-used contact detection feed breaker is wrong, this paper introduces a self ...
HUANG Chun
doaj +1 more source
Strong Lead‐Free Bioinspired Piezoceramics for Durable Energy Transducers
We fabricated brick‐and‐mortar lead‐free piezoceramics with Bi0.5Na0.5TiO3 monocrystal platelets as bricks and amorphous silica as mortar. The alignment of the bricks and the presence of the amorphous silica led to anisotropic residual stresses. These residual stresses increase the samples toughness, strength and durability while the brick alignment ...
Ruxue Yang +12 more
wiley +1 more source
A hybrid DC circuit breaker is the core protection equipment of a DC system, and its key parameters are critical to the products design and application, so the research on the influencing factors to such key parameters is of great significance to the ...
LUO Wenguang +4 more
doaj
An Improved DC Circuit Breaker Topology Capable of Efficient Current Breaking and Regeneration
An Improved DC Circuit Breaker Topology Capable of Efficient Current Breaking and ...
SMS Lumen (15767297) +3 more
core