Results 31 to 40 of about 1,493,934 (125)
A control method of fault current in MT-HVDC grid based on current limiter and circuit breaker [PDF]
In order to realize selective isolation of fault lines in multi-terminal high voltage DC (MT-HVDC) grids, it is necessary to ensure that the sound lines can still transmit power normally after the grounding fault occurs in a DC power network.
Wang, Sihua, Zhao, Lei, Zhou, Lijun
core +1 more source
In this work, metal oxide varistor (MOV) design optimization and switching control in the main circuit breaker (MCB) branch of a progressively switched hybrid DC circuit breaker (DCCB) is presented. A progressively switched hybrid DCCB can achieve faster
Md Rifat Kaisar Rachi (10978311) +1 more
core +1 more source
Technical Assessment of Hybrid HVDC Circuit Breaker Components under M-HVDC Faults
One of the technical challenges that needs to be addressed for the future of the multi-terminal high voltage direct current (M-HVDC) grid is DC fault isolation. In this regard, HVDC circuit breakers (DCCBs), particularly hybrid circuit breakers (H-DCCBs),
Saqib Khalid +6 more
doaj +1 more source
The black-box arc model is a tool that facilitates efficient research based on empirical studies in breaker design and analysis. However, its application has primarily focused on the design of ACCBs, with only a few instances of its implementation in the
Kyu-Hoon Park +2 more
doaj +1 more source
The direct current circuit breaker (DCCB) is extensively employed in DC microgrid applications to protect the network during faults. However, numerous DC converters are combined in parallel to form a DC microgrid, which creates a large network inductance.
S. M. Sanzad Lumen +3 more
core +1 more source
The modular multilevel converter (MMC) topology is very suitable for high voltage direct current (HVDC) system to achieve feasible power control, favorable black start capability as well as long-distance power transmission.
Lei Chen +4 more
doaj +1 more source
Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks
This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location.
Bhaskar Mitra +2 more
doaj +1 more source
This paper presents a comparative study of the electrical and thermal stresses on ABB's conventional hybrid type HVDC circuit breaker (CH-DCCB) and a novel integrated topology of solid-state fault current limiter (SSFCL) based H-DCCB in a multi-terminal ...
Wu Wenhuan (20260548) +5 more
core +1 more source
Dual-circuit hybrid circuit breaker
A DC fault will propagate quickly in a DC grid and results in significant DC voltage drop and large current increase. To protect the DC grid from the DC faults, the concept of hybrid HVDC circuit breaker (DCCB) is widely-accepted due to its low ...
Chuanyue Li +5 more
core +1 more source
A new direct current circuit breaker with current regeneration capability [PDF]
Direct current (DC) power systems are becoming very popular due to better control ability and equipment reliability thanks to the continuous development of power electronics.
S. M. Sanzad Lumen +5 more
core +1 more source

