Results 61 to 70 of about 1,493,934 (125)
Abstract Fast mechanical switches (FMSs) are critical components of DC circuit breakers (DCCBs), which require the switch action time to break to a sufficient distance within 3 ms in the DC line breaking scenario, while ensuring a long service life. The breaking mechanism significantly affects the current interruption capability of DCCBs. The operation
Puyi Cui +6 more
wiley +1 more source
A DC circuit breaker-based strategy for online insertion and bypass of UHV flexible DC valves
Multi-terminal flexible DC transmission is the primary means for transmitting renewable energy from deserts, gobi, and southeastern Tibetan regions. The online insertion and bypass of high- or low-voltage valves in modular multilevel converters (MMCs) is
Ying Xu +5 more
doaj +1 more source
Abstract Metal oxide varistors (MOVs) are extensively employed in DC circuit breakers (DCCBs) to suppress overvoltage, dissipate energy and build up voltage after interruption. Despite their widespread use, the performance of MOVs under short‐time, double energy absorption conditions is not well understood, posing a challenge to their application in ...
Chen Long +5 more
wiley +1 more source
Enhanced LV solid-state DC circuit breaker design with divided surge absorption technique [PDF]
This article presents an innovative design for low-voltage (LV) solid-state DC circuit breaker (SS-DCCB), incorporating the divided surge absorption technique (DSAT).
Moradian, M, Lie, TT, Gunawardane, K
core +3 more sources
Interlink Hybrid DC Circuit Breaker [PDF]
—To protect HVDC grids from DC faults, the concept of a hybrid DC circuit breaker is widely accepted due to its low conduction losses and fast interruption speed.
Chuanyue Li +5 more
core +1 more source
Ultra-Low on-State Voltage IGCT for Solid-State DC Circuit Breaker with Single-Switching Attribute
The performance of solid-state dc circuit breaker (SS-DCCB) is mainly determined by the on-state feature of power device. In this article, an optimized low on-state voltage integrated gate-commutated thyristor (LO-IGCT) for SS-DCCB is developed.
Ji, Weifeng +9 more
core +1 more source
The paper higlights the usage of GFM WTG to enable temporary blocking of the offshore converter in MT‐HVDC systems to reduce protection requirements. It is shown, that smaller DCCB series inductances can be used. During temporary blocking the AC power transfer is interupted but is returned quickly after the converter is brought back into operation ...
Christopher Klein +3 more
wiley +1 more source
Arc Characteristics in Multiple Pole DC Circuit Breakers
Due to the absence of zero crossings in a DC current compared to an AC current DC arc extinguishing is difficult in DC circuit breakers DCCB To overcome this difficulty of arc extinguishing DC circuit breakers are frequently designed and built by series ...
Dassanayake, C +4 more
core +1 more source
A low‐cost MMC submodule topology with fast DC fault handling capability
This paper proposes a modular multilevel converter (MMC) sub‐module structure with low switching loss and fast blocking function of DC bipolar short‐circuit fault current. The proposed structure is able to output levels of three voltage levels. Compared with the traditional MMC composed of full‐bridge submodule, its fault current blocking speed is ...
Yiqi Liu +5 more
wiley +1 more source
The development of high-performance DC circuit breakers (DCCBs) and rapid fault detection schemes is a crucial and challenging part of advancing Modular Multilevel Converter (MMC) HVDC grids.
Qiuyu Cao +4 more
doaj +1 more source