Results 111 to 120 of about 16,999 (226)
Fast Hybrid Circuit Breaker for Medium-Voltage DC and AC Railway Power Supply Networks: A Simulation-Based Study [PDF]
This paper investigates the performance of a medium-voltage hybrid circuit breaker designed for the protection of electrical power supply networks in railway transportation systems.
Ahmad Olyaei, Rozbeh Asad
doaj
Delays in Protection Devices and Their Effects on Selectivity: The Reaction Time Gap
This Paper investigates how the internal delays of circuit breakers until the limitation of the fault current affect the selectivity of a low-voltage direct current (LVDC)-grid under short-circuit conditions.
Johannes Gehring +5 more
doaj +1 more source
Advanced Test Circuit for DC Circuit Breakers
QC ...
Augustin, Tim +2 more
openaire +1 more source
A Survey of Hybrid Circuit Breakers: Component-Level Insights to System-Wide Integration
This survey provides a comprehensive review of hybrid circuit breakers and their applications in 1 kV to 800 kV, both alternating current and direct current systems.
Yuchen He +3 more
doaj +1 more source
Under DC voltage, charge accumulates on the break insulation of mechanical DC circuit breakers, distorting the local electric field, which increases the risk of break insulation failure.
Wenxia Sima +4 more
doaj +1 more source
Developments in space power components for power management and distribution [PDF]
Advanced power electronic components development for space applications is discussed. The components described include transformers, inductors, semiconductor devices such as transistors and diodes, remote power controllers, and transmission ...
Renz, D. D.
core +1 more source
The Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
This paper explains the working principles, supported by simulation results, of a new converter topology intended for HVDC applications, called the alternate arm converter (AAC).
Critchley, R +6 more
core +1 more source
Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems
The first-ever Ukraine cyberattack on power grid has proven its devastation by hacking into their critical cyber assets. With administrative privileges accessing substation networks/local control centers, one intelligent way of coordinated cyberattacks ...
Ginter, Andrew +4 more
core +1 more source
Voltage Source Converters (VSCs) operating as active rectifiers inherently lack current-limiting capabilities for faults occurring on the DC side due to the presence of freewheeling diodes in IGBT or MOSFET structures.
Evangelos E. Pompodakis +1 more
doaj +1 more source
The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Given, M.J. +6 more
core