Results 161 to 170 of about 41,126 (268)

Economic and environmental implications of the development of UASB reactors in Mexico for sustainable industrial wastewater treatment

open access: yesThe Canadian Journal of Chemical Engineering, EarlyView.
Abstract The objective of this work is to demonstrate that the inclusion of an up‐flow anaerobic sludge bed (UASB reactor) within an industrial wastewater treatment plant reduces the plant's investment and operating costs compared to a system based solely on conventional complete‐mix activated sludge (CMAS), operating under the same design principles ...
Juan Manuel Morgan‐Sagastume   +1 more
wiley   +1 more source

Review of CFD modelling techniques for single‐phase and multiphase flow in static mixers

open access: yesThe Canadian Journal of Chemical Engineering, EarlyView.
This review synthesizes computational fluid dynamics (CFD) approaches for static mixers, linking hydrodynamics to pressure drop, particle/droplet distributions, mixing metrics, and heat‐transfer performance to guide modelling choices and design decisions. Abstract Static mixers enable compact and low‐energy intensification.
Jussan Jaeger   +7 more
wiley   +1 more source

Advanced FCS-MPC strategy for optimized control and efficiency in photovoltaic inverters. [PDF]

open access: yesSci Rep
Dekhane A   +6 more
europepmc   +1 more source

Nonlinear permuted Granger causality

open access: yesCanadian Journal of Statistics, EarlyView.
Abstract Granger causality is an established, contentious method that seeks causal temporal connections via association and precedence. While not true causal inference, it assists in mapping networks of information flow that may warrant further study.
Noah D. Gade, Jordan Rodu
wiley   +1 more source

Energy Landscapes in Chemical Reactions and Transport

open access: yesChemPhysChem, Volume 26, Issue 6, March 15, 2025.
Kinetics/dynamics of chemical reactivity and transport of chemical species in a solid are both determined by the energy landscape in which they take place. Discussing common grounds but also distinct differences may help in advancing the understanding in both fields.
Karl‐Michael Weitzel
wiley   +1 more source

An Ultra‐Low‐Power Biopotential Acquisition Analog Front‐End Chip for Wearable Devices

open access: yesInternational Journal of Circuit Theory and Applications, EarlyView.
A 0.8‐V, 1.2‐μW biopotential AFE combines a chopper‐stabilized CCIA with dual‐time‐scale EDO management. The slow DSL preserves > 1 GΩ input impedance, whereas an event‐triggered fast‐recovery path shortens return to the linear range after abrupt electrode‐offset disturbances. ABSTRACT A 0.8‐V, 1.2‐μW biopotential analog front‐end (AFE) IC is presented
Zhang Xin   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy