Results 161 to 170 of about 1,539 (216)

Sizing of Packed Deaeration Columns

open access: yesChemical Engineering and Technology, 2019
Removal of oxygen from feedwater is of paramount importance for safe boiler operation. Insufficient extraction of oxygen in deaeration vessels will lead to limited efficiency of oxygen scavengers and unsafe plant operation. The presented sizing procedure
Srbislav Genic   +2 more
exaly   +2 more sources

Deaeration

Shivanand Shankarrao Shirkole
exaly   +4 more sources

Deaeration of powders in hoppers

Powder Technology, 1980
Abstract Air is entrained when fine powders are loaded from a height into a container. The air takes some time to dissipate, which gives rise to problems in bag filling, silo loading, charging of bulk tankers etc. An analysis of the percolation of air through a granular bed is presented, together with an analytical solution via consolidation theory ...
P.G. Murfitt, P.L. Bransby
openaire   +1 more source

The deaeration of fine powders

Powder Technology, 1987
Abstract A theoretical analysis has been made of the rate of deaeration of a dilated bed of fine particles. The work is relevant to the phenomenon of flooding, since flooding is said to occur only when the material is dilated. This analysis is more general than previous analyses, and makes allowance for the change in bed depth as well as the change ...
T. Rathbone, R.M. Nedderman
openaire   +1 more source

Vacuum Deaerator Design

Journal of Engineering for Power, 1961
A study was made of vacuum desorption of oxygen and carbon dioxide from water using 1-in. Raschig rings in a 2-ft-diameter tower having a maximum packing height of 22 ft. The effect of various operating variables on the HTU was investigated and the data correlated to give a practical basis for designing vacuum deaerators.
A. W. Kingsbury, E. L. Phillips
openaire   +1 more source

A Method for Deaerating Water

Journal of the Hydraulics Division, 1969
In using hot-film anemometry for turbulence studies in water and in studying reaeration in water with no oxygen demand, there is a need to remove dissolved gases from water. This may be accomplished by putting the water into an environment in which it is supersaturated.
William H. C. Maxwell, Edward R. Holley
openaire   +1 more source

Offshore Membrane Deaeration as a Replacement for Vacuum Tower Deaeration - A Comparative Study

SPE Annual Technical Conference and Exhibition, 2015
Abstract A membrane deaeration pilot study undertaken on seawater from an onshore seawater intake, successfully demonstrated removal of dissolved oxygen to less than 10 parts per billion without the use of chemical oxygen scavenger. To assess the commercial viability of adapting membrane deaeration technology to offshore oil and gas ...
Stephen Van Pelt, Holly Churman
openaire   +1 more source

Development of a Scrubber in the Deaerator

Journal of Pressure Vessel Technology, 2015
A new design of a scrubber has been developed and used in a deaerator. Deaeration of feed water in the boiler system is an essential process in industry today. Any facilities operating with steam have at least one deaerator to remove dissolved oxygen from the feed water.
openaire   +1 more source

NOVEL DEAERATOR DESIGN

Anti-Corrosion Manual, 1973
One of the most compact deaerators on the market for producing non-corrosive boiler feed water has been introduced by Neckar Water Engineering Ltd. A feature of the design is the introduction of a steam lift pump, based on the principle of an air lift.
openaire   +1 more source

Home - About - Disclaimer - Privacy