Results 71 to 80 of about 183,014 (291)

Al–Cu Composite Casting of Laser‐Deoxidized Copper: Bonding, Interfacial Chemistry, and Thermal Conductivity

open access: yesAdvanced Engineering Materials, EarlyView.
This study investigates laser‐based oxide removal of Cu inserts in oxygen‐free conditions and examines long‐term oxidation kinetics and surface chemistry under different atmospheres via X‐ray photoelectron spectroscopy. Al–Cu compound casting with differently oxidized surfaces is performed, and intermetallic phase formation, morphology, and thermal ...
Timon Steinhoff   +9 more
wiley   +1 more source

ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

open access: yesNuclear Engineering and Technology, 2013
Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor ...
VIKAS JAIN   +5 more
doaj   +1 more source

A conceptual design study of pool-type sodium-cooled fast reactor with enhanced anti-seismic capability

open access: yesMechanical Engineering Journal, 2020
The authors are developing the design concept of the pool-type sodium-cooled fast reactor (SFR) that addresses Japan’s specific siting conditions such as earthquakes and meets safety design criteria (SDC) and safety design guidelines (SDG) for Generation
Shigenobu KUBO   +10 more
doaj   +1 more source

Corrosion and Process Analysis of a Preoxidized MgO Recyclate‐Based Cermet Anode in Laboratory‐Scale Na‐Cryolite Molten Salt Electrolysis of Aluminum at 1000°C

open access: yesAdvanced Engineering Materials, EarlyView.
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk   +7 more
wiley   +1 more source

Development of probabilistic risk assessment methodology of decay heat removal function against combination hazard of low temperature and snow for sodium-cooled fast reactors

open access: yesMechanical Engineering Journal, 2018
A probabilistic risk assessment (PRA) should be performed not only for earthquake and tsunami which are major natural events in Japan but also for other natural external hazards. However, PRA methodologies for other external hazards and their combination
Hiroyuki NISHINO   +2 more
doaj   +1 more source

Raman Spectroscopic Identification of Oxide Phases in a Corroded MgO–Steel Composite Anode Used in Aluminum Molten Salt Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Micro‐Raman spectroscopy is applied to characterize corrosion products in a recycled‐based MgO–316L steel composite anode after molten salt electrolysis. A depth‐dependent Fe–O/Fe–Al–O layer sequence of magnetite, hercynite, and an Al‐doped magnetite transition zone is identified.
Felix Drechsler   +9 more
wiley   +1 more source

Verification of the ability of safe activation of the isolated DHR loop of the ALLEGRO reactor in the event of an accident with complete loss of power

open access: yesNuclear Engineering and Technology
The development of the ALLEGRO gas-cooled demonstration reactor dates back to the early days of Generation 4 reactors. A more detailed conceptual design is currently being developed, which includes thermohydraulic studies of the reactor's safety features.
Pavel Zácha, Václav Železný
doaj   +1 more source

Interaction of MgO Recyclate‐Based Cermet Anode With KF‐AlF3‐Al2O3 at 800°C During Laboratory Scale Aluminum Molten Salt Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
A carbon‐free, as‐sintered MgO–steel cermet anode, fabricated via cold isostatic pressing using MgO–C refractory recyclate, was evaluated under laboratory‐scale K‐cryolite electrolysis at 800°C. Operation at this reduced temperature, combined with the electrolyte's limited electrical conductivity, led to an increase in cell voltage.
Farhan Hossain   +7 more
wiley   +1 more source

SCALE ANALYSIS OF DECAY HEAT REMOVAL SYSTEM BETWEEN HTR-10 AND HTR-PM REACTORS UNDER ACCIDENTAL CONDITIONS [PDF]

open access: yes
The 10 MW high-temperature gas-cooled test module (HTR-10) is a graphite-moderated and helium-cooled pebble bed reactor prototype that was designed to demonstrate the technical and safety feasibility of this type of reactor project under normal and ...
ALVIM, Antonio C. M   +2 more
core  

Risk-informed approach to the safety improvement of the reactor protection system of the AGN-201K research reactor

open access: yesNuclear Engineering and Technology, 2020
Periodic safety reviews (PSRs) are conducted on operating nuclear power plants (NPPs) and have been mandated also for research reactors in Korea, in response to the Fukushima accident.
Ibrahim Ahmed, Enrico Zio, Gyunyoung Heo
doaj   +1 more source

Home - About - Disclaimer - Privacy