Results 111 to 120 of about 64,627 (246)

First‐in‐human outpatient management of recurrent NMIBC with the Multi4 instrument

open access: yesBJU International, EarlyView.
Objectives To evaluate the feasibility, safety and diagnostic performance of outpatient management of recurrent non‐muscle‐invasive bladder cancer (NMIBC) under local anaesthesia using the Multi4 instrument, a series of preclinical studies were performed followed by a first‐in‐human clinical investigation.
Miden Melle‐Hannah   +4 more
wiley   +1 more source

Refining the treatment of immune checkpoint inhibitor–associated myocarditis: Challenges, innovations and rechallenge considerations

open access: yesBritish Journal of Pharmacology, EarlyView.
Immune checkpoint inhibitor (ICI)‐associated myocarditis has emerged as a severe and clinically complex immune‐related toxicity that poses significant challenges for therapeutic decision‐making in routine cardio‐oncological care. High‐dose corticosteroids remain the first‐line therapy, yet their timing, dosage and tapering require careful clinical ...
Raluca I. Mincu   +10 more
wiley   +1 more source

Arrhythmias associated with immune checkpoint inhibitor therapy—A clinical perspective

open access: yesBritish Journal of Pharmacology, EarlyView.
Immune checkpoint inhibitors (ICIs) have transformed cancer therapy but are associated with a growing spectrum of cardiovascular immune‐related adverse events. Among these, arrhythmias represent a rare yet potentially life‐threatening complication. ICI‐induced arrhythmias encompass a wide clinical spectrum, including atrial arrhythmias, conduction ...
Dong Wang   +4 more
wiley   +1 more source

Catheter Ablation: Evolution and Efficiencies

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT The present review includes a discussion the goals and pitfalls of efficiency in the medical profession, a historical perspective on the evolution of catheter ablation in the field of electrophysiology (EP), and the data regarding the relationship between efficiency and outcomes in the EP lab. Focus on efficacy is critical to maximize resource
Aravind G. Kalluri, Bradley P. Knight
wiley   +1 more source

The Effect of Pacemakers and Defibrillators on Distortion in 2 Magnetic Resonance Imaging (MRI) Sequences Commonly Used in Radiation Oncology Practice—3D True Fast Imaging with Steady State Precession (TrueFISP) at 0.35T MR-Linear Accelerator (LINAC) and 3D T1 at 3T MR Simulator

open access: yesRadiation
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a ...
Alireza Omidi   +3 more
doaj   +1 more source

Safety and Utility of Smartphone‐Based Heart Monitors in Pediatric Patients With Cardiovascular Implantable Electronic Devices

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
Smartphone heart monitors in pediatric CIEDs: A pilot study. Smartphone heart monitors did not induce EMI in children with CIEDs, enabling reliable heart rate measurement and accurate identification of ventricular non‐captures. ABSTRACT Background Portable heart monitors enable on‐demand electrocardiogram (ECG) recordings and enhance symptom‐rhythm ...
Chun‐Lok Ho   +3 more
wiley   +1 more source

Terminal S Wave Pattern in Lead V3 as a Simple Marker for Ventricular Tachycardia Risk Stratification in Patients With Repaired Tetralogy of Fallot

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Introduction Patients with repaired tetralogy of Fallot (rTOF) remain at risk of ventricular tachycardia (VT). This risk is most commonly related to slow conduction within the septal isthmus, which is defined as the region between the ventricular septal defect (VSD) patch and adjacent valvular annuli.
Yuki Matsuoka   +8 more
wiley   +1 more source

Time‐Dependent Diagnostic Yield and Therapeutic Impact of Implantable Loop Recorders, Brugada Syndrome as the Exception

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
Diagnostic yield and therapeutic impact varied substantially according to the indication for implantation. Actionable diagnoses were concentrated in the early follow‐up period for syncope and palpitations, whereas late atrial fibrillation detection after cryptogenic stroke could still modify antithrombotic management. In contrast, patients with Brugada
Luigi Cocchiara   +17 more
wiley   +1 more source

Brugada Syndrome in the Pediatric Population: Diagnostic Challenges and Clinical Outcome—Results of the German Multicenter Study COGIA

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
The study examines 76 patients of the German multicenter study COGIA with suspected BrS in 12 centers in Germany. Thirty‐nine patients met the current ESC diagnostic criteria, 34 of whom met the Shanghai Score criteria. Four major arrhythmic events (ACA, SCD, appropriate ICD shock) occurred in the cohort (5.3%), all in the group of patients fulfilling ...
Lea Lippert   +35 more
wiley   +1 more source

Clinical Outcomes After Catheter Ablation in Patients With Structural Heart Disease and Ventricular Fibrillation

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Introduction In patients with ischemic cardiomyopathy (ICM), recurrent VF may be treated with catheter ablation by targeting triggering premature ventricular complexes (PVCs) and/or ventricular scar homogenization. Data on optimal ablation strategies in patients with non‐ischemic cardiomyopathy (NICM) remain limited.
Kenji Hashimoto   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy