Results 151 to 160 of about 1,744,611 (325)

The Long Term Effects of a 12‐Session Community Exercise Program on Health Measures in Cancer Patients

open access: yesAging and Cancer, EarlyView.
ABSTRACT Purpose To assess the long‐term effects of a community cancer exercise program on quality of life, fatigue, weight, waist circumference, physical activity levels, lower extremity strength, body mass index (BMI), heart rate, and blood pressure, across non‐metastatic and metastatic patients.
Isaac Oppong, Roozbeh Naemi
wiley   +1 more source

SO(4) Landau models and matrix geometry

open access: yesNuclear Physics B, 2018
We develop an in-depth analysis of the SO(4) Landau models on S3 in the SU(2) monopole background and their associated matrix geometry. The Schwinger and Dirac gauges for the SU(2) monopole are introduced to provide a concrete coordinate representation ...
Kazuki Hasebe
doaj  

Eigenvectors in terms of reduced complements of minor determinants [PDF]

open access: yesarXiv
Eigenvectors associated with non-degenerate eigenvalues are shown to correspond to columns of the adjugate of the characteristic matrix. Degenerate eigenvalues are associated with eigenvectors that correspond to reduced complement tensors of minor determinants of the characteristic matrix. These observations are corroborated by a description of the non-
arxiv  

Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray   +9 more
wiley   +1 more source

The effect of kV imaging dose on PTV and OAR planning constraints in lung SBRT using stereoscopic/monoscopic real‐time tumor‐monitoring system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley   +1 more source

Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

Performance analysis of control allocation using data‐driven integral quadratic constraints

open access: yesAdvanced Control for Applications, Volume 4, Issue 4, December 2022., 2022
Abstract A new method is presented for evaluating the performance of a nonlinear control allocation system within a linear control loop. To that end, a worst‐case gain analysis problem is formulated that can be readily solved by means of well‐established methods from robustness analysis using integral quadratic constraints (IQCs).
Manuel Pusch   +2 more
wiley   +1 more source

Evaluation of the dose reduction effect of crystalline lens exposure in cone‐beam computed tomography with bismuth eye shield for image‐guided radiation therapy: An anthropomorphic phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida   +5 more
wiley   +1 more source

Digital Light Processing of 2D Lattice Composites for Tunable Self‐Sensing and Mechanical Performance

open access: yesAdvanced Engineering Materials, EarlyView., 2023
The study presents the mechanical and in situ sensing performance of digital light processing‐enabled 2D lattice nanocomposites under monotonic tensile and repeated cyclic loading, and provides guidelines for the design of architectures suitable for strain sensors and smart lightweight structures.
Omar Waqas Saadi   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy