Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant‐supported prosthetic systems under varying bone conditions using finite element analysis. Materials and Methods Four three‐dimensional (3D) finite element models were developed based on two different anatomical
Ercin Samunahmetoglu   +2 more
wiley   +1 more source

Zirconia abutments and reduced crown-to-implant ratios: Insights into stress distribution. [PDF]

open access: yesBraz Oral Res
Grassi L   +7 more
europepmc   +1 more source

Clinical implications of misfit in multiunit implant‐supported fixed dental prostheses: A systematic review

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This systematic review aimed to evaluate the long‐term effects of misfit on the clinical outcomes of multiunit implant‐supported fixed dental prostheses (ISFDPs). Methods An electronic literature search was conducted up to December 2025 across five databases: MEDLINE (via Ovid), Embase (via Ovid), Web of Science, the Cochrane Library ...
Zijing He   +4 more
wiley   +1 more source

Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To compare the relative accuracy of intraoral photogrammetry (IPG) and intraoral scan (IOS) with conventional scan bodies (IOS‐CB) for complete‐arch implant impressions, using the conventional splinted open‐tray impression digitized with a laboratory scanner (COT‐LS) as the reference standard.
Sherif Aly Sadek   +3 more
wiley   +1 more source

Assessing angular and linear misfits in zirconia frameworks through torque/time graph interpretation: A proof of concept

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose Passive fit in implant‐supported complete‐arch prostheses is the key to long‐term success. The aim of this in vitro, proof‐of‐concept study was to examine whether torque/time graphs generated from a surgical motor during the prosthetic screw insertion process show consistent patterns of digitally controlled angular and linear misfits ...
Carla Vidal‐Ponsoda   +5 more
wiley   +1 more source

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete‐arch implant‐supported digital impressions: An in vitro study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose The purpose of this in vitro study was to compare the reverse scan body (RSB) and standard scan body (SCB) protocols for complete‐arch implant‐supported digital impressions with respect to root mean square (RMS), linear deviation, and angular deviation values, as well as clinical passive fit.
Rabia Kilicaslan Dasdelen   +2 more
wiley   +1 more source

Comparative trueness of complete‐arch implant position acquisition using auxiliary geometric device–aided and noncalibrated scanbody–based intraoral scanning versus smartphone‐based and dedicated extraoral photogrammetry

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To compare the trueness of four techniques for complete‐arch implant position acquisition: intraoral implant scanning (IOIS) using auxiliary geometric devices (AGDs), IOIS using horizontally extended noncalibrated scanbodies (NCSBs), smartphone‐based extraoral photogrammetry (EPG), and EPG with a dedicated scanner, with the null ...
Mohamed Sherif Omar   +4 more
wiley   +1 more source