Results 201 to 210 of about 5,813 (224)
Some of the next articles are maybe not open access.
Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants
Journal of the Mechanical Behavior of Biomedical Materials, 2018Frequent reports attest to the various advantages of tapered implant/abutment interfaces (IAIs) compared to other types of interfaces. For this reason, a conical IAI was designed as part of the development of a PEEK (polyetheretherketone)-based dental implant.
Andreas Dominik, Schwitalla +6 more
openaire +4 more sources
Text condition embedded regression network for automated dental implant abutment design
Expert Systems with ApplicationsMianjie Zheng +7 more
openaire +3 more sources
Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2005AbstractThe objective of this study was to investigate the influence of implant/abutment joint designs on abutment screw loosening in a dental implant system, using nonlinear dynamic analysis of the finite element method (FEM). This finite element simulation study used two dental implant systems: the Ankylos implant system (Degusa Dental, Hanau, German)
Tsuyoshi, Kitagawa +4 more
openaire +2 more sources
Clinical Implant Dentistry and Related Research, 2015
AbstractPurposeThe aim of this study is to utilize an in vitro dynamic loading model to assess the potential risk of bacterial invasion into the Implant Abutment Interface (IAI) microgap of dental implants with sloped marginal design.Materials and MethodsForty implants were divided into two groups (n = 20 per group) based on implant marginal design ...
Theofilos, Koutouzis +2 more
openaire +2 more sources
AbstractPurposeThe aim of this study is to utilize an in vitro dynamic loading model to assess the potential risk of bacterial invasion into the Implant Abutment Interface (IAI) microgap of dental implants with sloped marginal design.Materials and MethodsForty implants were divided into two groups (n = 20 per group) based on implant marginal design ...
Theofilos, Koutouzis +2 more
openaire +2 more sources
European journal of oral implantology, 2018
To evaluate whether there are aesthetic and clinical benefits to using a newly designed abutment (Curvomax), over a conventional control abutment (GingiHue).A total of 49 patients, who required at least two implants, had two sites randomised according to a split-mouth design to receive one abutment of each type at seven different centres.
Esposito M. +9 more
openaire +3 more sources
To evaluate whether there are aesthetic and clinical benefits to using a newly designed abutment (Curvomax), over a conventional control abutment (GingiHue).A total of 49 patients, who required at least two implants, had two sites randomised according to a split-mouth design to receive one abutment of each type at seven different centres.
Esposito M. +9 more
openaire +3 more sources
Effect of platform design of dental implant abutment on loosening and fatigue performance
Engineering Failure AnalysisFei Sun +5 more
openaire +1 more source

