Results 71 to 80 of about 10,385,827 (157)
In Vitro Micro-CT Assessment of a Novel Implant–Abutment Connection Under Static and Cyclic Loading
The implant–abutment connection (IAC) is a critical determinant of the mechanical and biological performance of dental implants. Connection design and insertion torque may influence fatigue resistance, micromovement, and microgap formation, thereby ...
Marco Tallarico +10 more
doaj +1 more source
Background Long-term success and patient satisfaction of dental implant systems can only be achieved by fulfilling clinical as well as biological needs related to maintenance, aesthetics, soft tissue sealing, and osseointegration, among others.
Milleret, V. +11 more
core +1 more source
Tightening techniques for the retaining screws of universal abutment
Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws.
Alexandre Wittcinski REGALIN +5 more
doaj +1 more source
Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC) Crowns [PDF]
BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded.
Bürki, Alexander +14 more
core +1 more source
Investigation of the Effects of Abutment and Implant Length on Stability of Short Dental Implants
Diş hekimliğinde bulunan farklı sorunları çözmek için dental implantların kullanımı hızla artmaktadır. Dental implantların başarı oranları da hastalar için oldukça önemlidir. Kısa dental implantlar, hastaların kemik seviyesine bağlı olarak çok popüler ve
BİLGİN, M. Burak +4 more
core +1 more source
Effect of Platform Switching on Peri-Implant Bone Levels
Objective: To radiographically assess and compare mean marginal bone loss (MBL) between platform-switched (PS) and platform-matched (PM) dental implants after functional loading Study Design: Quasi-experimental Study Place & Duration of Study: 89 ...
Danish Azeem Khan +2 more
doaj +1 more source
In aesthetically demanding locations of the dentition, the replacement of a single tooth by means of an oral implant is often difficult because of technical limitations of the abutment systems used.
Sutter, F +4 more
core
Accuracy of one-versus two-phase photogrammetry implant impression system: an in-vitro study
Dental implants using digital technologies have become more popular for partial and fully edentulous patients. This in-vitro study aimed to compare the accuracy of one- and two-phase photogrammetry implant impression techniques.
Atith Jiranaphawiboon +2 more
doaj +1 more source
Ultrasonic Oscillations for Conservative Retrieval of a Rare Fracture of Implant Healing Abutment
Dental implants can be rendered useless because of complications related to implant components such as the fracture of abutment screw and prosthetic retaining screw.
Sonika Bakshi +2 more
core +1 more source
The loss of anterior teeth has a significant impact on masticatory function and facial aesthetics, making dental implants a widely used rehabilitative solution.
gunagung syahrul nizam sulkan +4 more
doaj +1 more source

