Results 61 to 70 of about 56,590 (319)
Purpose A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even ...
Alexander Schmidt +3 more
doaj +1 more source
Deciduous enamel 3D microwear texture analysis as an indicator of childhood diet in medieval Canterbury, England [PDF]
This study conducted the first three dimensional microwear texture analysis of human deciduous teeth to reconstruct the physical properties of medieval childhood diet (age 1-8yrs) at St Gregory's Priory and Cemetery (11th to 16th century AD) in ...
Deter, Chris +7 more
core +3 more sources
The effect of temperature controllers that are commonly used in freeze‐casting is investigated in this work. Temperature controllers are observed to generate a voltage in the slurry. Microstructural alignment and ultimate compressive strength data show this voltage to interfere with the ability to align the microstructure using magnetic fields ...
Maddie A. Schmitz, Steven E. Naleway
wiley +1 more source
Interproximal Distance Analysis of Stereolithographic Casts Made by CAD-CAM Technology: An in Vitro Study [PDF]
Statement of problem The accuracy of interproximal distances of the definitive casts made by computer-aided design and computer-aided manufacturing (CAD-CAM) technology is not yet known.
Hoffman, Melanie +2 more
core +2 more sources
Effect of Different Impression Techniques on Marginal Fit of Restoration – An In Vitro Study
Introduction: Impression making is one such important clinical step, which is critical in the accurate fitting of resulting prostheses. Impression making itself depends on the type of material and the impression technique used to record the details ...
Priyanka S. Raghav +4 more
doaj +1 more source
Optimizing Anterior Implant Outcome Immediately After Implant Placement and Grafting by Using Patient’s Extracted Teeth: A Case Report [PDF]
Optimizing anterior implant outcome using patient’s extracted teeth. Successful implant treatment in the anterior maxilla is predicated on providing a functional and esthetically acceptable outcome.
Banez, Jay Darryl +3 more
core +1 more source
This study reports the fabrication of trabecular bioactive glass scaffolds (composition “1d”: 46.1SiO2‐28.7CaO‐8.8MgO‐6.2P2O5‐5.7CaF2‐4.5Na2O wt%) through vat photopolymerization and the relevant results from mechanical testing and in vivo implantation procedures in rabbit femora, showing great promise for bone tissue engineering applications.
Dilshat Tulyaganov +8 more
wiley +1 more source
Comparison of Accuracy and Reproducibility of Casts Made by Digital and Conventional Methods [PDF]
Statement of problem Little peer-reviewed information is available regarding the accuracy and reproducibility of digitally fabricated casts compared to conventional nondigital methods.
Cho, Seok-Hwan +3 more
core +1 more source
A 3D bone scaffold with osteogenic properties and capable of hardening in vivo is developed. The scaffold is implanted in a ductile state, and a phase transformation of the ceramic induces the stiffening and strengthening of the scaffold in vivo. Abstract Calcium phosphate 3D printing has revolutionized customized bone grafting.
Miguel Mateu‐Sanz +7 more
wiley +1 more source
Comparative analysis of different implant impression techniques: An In vitro study
Introduction: Dental implants have emerged as the treatment of choice for restoring missing teeth in situations that require functional and aesthetic replacements.
Radhika R Agnihotri +5 more
doaj +1 more source