Results 121 to 130 of about 27,567 (266)
ABSTRACT Objective To assess the clinical, radiographic and patient‐reported outcome measures, and the success of screw‐retained one‐piece monolithic zirconia implant‐supported restorations in the posterior region during a 1‐year follow‐up. Methods In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum
Vincent J. J. Donker+4 more
wiley +1 more source
ABSTRACT Objective To evaluate the effectiveness of Sub‐periosteal Peri‐implant Augmented Layer (SPAL) technique performed with deproteinized bovine bone mineral (DBBM), delivered either as particulate (pDBBM) or block (bDBBM), in correcting a peri implant bone dehiscence (PIBD).
Mattia Severi+4 more
wiley +1 more source
ABSTRACT Objectives WNT10A mutations are associated with tooth agenesis. This study aimed to assess the clinical outcomes of dental implants in patients carrying WNT10A mutations with different molecular statuses and phenotypes over a long‐term follow‐up period. Materials and Methods Patients with tooth agenesis were screened by whole‐exome sequencing (
Jiaqi Dou+6 more
wiley +1 more source
ABSTRACT Objectives This experimental study compared the accuracy of implant insertion using the free‐hand (FH) technique, static computer‐aided surgery (S‐CAIS), or dynamic computer‐assisted surgery (D‐CAIS) and to evaluate the correlation of learning curves between surgeons' experience and surgical time.
Joscha Gabriel Werny+6 more
wiley +1 more source
Five‐Year Results of One‐Piece Zirconia Oral Implants Supporting Three‐Unit Fixed Dental Prostheses
ABSTRACT Objectives The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one‐piece zirconia implants fabricated from 3Y‐TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three‐unit fixed dental prostheses (FDP) after five years in function. Materials and Methods Twenty‐
Ralf‐Joachim Kohal+4 more
wiley +1 more source
Utilizing Intraoral Scanning and Computer-Aided Design/Manufacturing for Creating a New Dental Crown to Match an Existing Removable Prosthesis: A Case Report [PDF]
Pongsakorn Apinsathanon
openalex +1 more source
ABSTRACT Introduction This study aimed to investigate the combined effect of trans‐mucosal abutment height (TmAH) and restorative emergence angle (REA) on marginal bone loss (MBL) around bone‐level implants. Methods Implant radiographs 12–18 months after crown placement (T0) and at least one year later (T1) were retrospectively analyzed.
Jonathan Misch+7 more
wiley +1 more source
ABSTRACT Objective The aim of this study was to investigate the influence of bone microstructure on the accuracy of robot‐assisted dental implant surgery. Materials and Methods This retrospective study analyzed 52 patients who received robot‐assisted implant surgery between January 2023 and October 2023.
Wenxi Dong+6 more
wiley +1 more source
Evaluation of the effects of geometric design and surface properties of dental implants on marginal bone loss and bone quality by fractal analysis. [PDF]
Karabağ M, Gümrükçü Z, Bayrak S.
europepmc +1 more source
ABSTRACT Objectives In vitro analysis of the influence of vertical peri‐implant soft tissue thickness (STT) on nonsurgical and surgical implant surface decontamination efficacy. Material and Methods A total of 360 implants were dipped in indelible color to imitate biofilm contamination, distributed to 30°, 60° or 90° angulated bone defect models and in
Annika Rahner+5 more
wiley +1 more source