Results 11 to 20 of about 27,567 (266)

Connector design in a long-span-fixed dental prosthesis: A three-dimensional finite element analysis

open access: goldIndian Journal of Dental Research, 2013
The goal of every prosthetic management is to simulate nature and be in harmony with nature within the physiological limits. The occlusal forces on a fixed dental prosthesis are transmitted to the surrounding structures through pontics, connectors and retainers and more stresses are seen at the connector region.
BH Harshitha Gowda, CL Satish Babu
openalex   +5 more sources

Digitally designed fixed dental prosthesis with stress breaking effect using non-rigid connector for pier abutment: A case report [PDF]

open access: goldActa Marisiensis - Seria Medica, 2022
Abstract Rigid connectors between pontic and retainer are preferred way of fabricating fixed partial dentures for many decades as they provide desirable strength, retention and stability to the prosthesis. However, it is not ideal for cases such as lone-standing abutments (pier abutment), maligned teeth where occlusal stress can extrude ...
Manu Rathee   +5 more
openalex   +3 more sources

Cantilever resin-bonded fixed dental prosthesis to substitute a single premolar: Impact of retainer design and ceramic material after dynamic loading

open access: hybridJournal of Prosthodontic Research, 2023
To evaluate the influence of retainer design and ceramic materials on the durability of minimally invasive cantilever resin-bonded fixed dental prostheses (RBFDPs) after artificial aging.One hundred caries-free human mandibular molars were prepared as abutments for all-ceramic cantilevered fixed dental prostheses using the following retainer designs ...
Ammar T. Kasem   +3 more
openalex   +5 more sources

Implant biomechanics relating to the dental implant and prosthesis design: In-vitro strain gauge analysis and finite element analysis [PDF]

open access: goldAIP Advances
Background: Biomechanics of an implant-supported prosthesis play a key role in the success or failure of rehabilitation of missing teeth. This study aimed to analyze biomechanical factors, such as an implant design and prosthesis design for a single implant-supported prosthesis.
Aqsa Shaukat   +3 more
openalex   +3 more sources

Durability of cantilever inlay-retained fixed dental prosthesis fabricated from multilayered zirconia ceramics with different designs

open access: yesJournal of the Mechanical Behavior of Biomedical Materials, 2023
The purpose of this in-vitro study was to investigate the effect of framework design on fracture resistance and failure modes of cantilever inlay-retained fixed partial dentures (IRFDPs) fabricated from two multilayered monolithic zirconia materials.Seventy-two natural premolar teeth were prepared as abutments for cantilever IRFDPs using three designs:
Al-Dwairi, Ziad N   +3 more
openaire   +7 more sources

"All on short" prosthetic-implant supported rehabilitations [PDF]

open access: yes, 2017
Objectives. Short implants are increasing their popularity among clinicians who want to fulfill the constant demanding of fixed prosthetic solutions in edentulous jaws.
Bernardi, S.   +6 more
core   +1 more source

Fem and Von Mises analysis of OSSTEM ® dental implant structural components: evaluation of different direction dynamic loads [PDF]

open access: yes, 2018
PURPOSE: The objective of this investigation is to study prosthodontics and internal components resistance to the masticatory stress and considering different force directions by using Finite Element Method analysis (FEM).
Bramanti, E1   +10 more
core   +1 more source

Impending Total Airway Collapse Involving a Maxillary Removable Partial Denture: A Clinical Report [PDF]

open access: yes, 2018
This article presents a rare incident of a bilateral maxillary removable partial denture as an airway foreign body. The removable partial denture and the surrounding soft tissue irritation caused partial obstruction of the airway.
Maroulakos, Georgios   +1 more
core   +2 more sources

The Randomized Shortened Dental Arch Study: Tooth Loss [PDF]

open access: yes, 2010
The evidence concerning the management of shortened dental arch (SDA) cases is sparse. This multi-center study was aimed at generating data on outcomes and survival rates for two common treatments, removable dental prostheses (RDP) for molar replacement ...
Busche, E.   +20 more
core   +1 more source

Home - About - Disclaimer - Privacy