Results 31 to 40 of about 107,681 (307)
Photoelastic Stress Analysis in Prosthetic Implants of Different Diameters: Mini, Narrow, Standard or Wide [PDF]
Purpose: This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis.
Marcelo Coelho Goiato +4 more
doaj +1 more source
Introduction: the use of custom implants is a very common treatment; we assess and compare their behavior against that of conventional implants. This study aimed to make sure that the stress zones of the custom implant are different from those presented ...
Byron Vinicio Velasquez-Ron +3 more
doaj +1 more source
Stress distribution in the peri-implant area of pure titanium and titanium-zirconium small implants
Aim: In dental implant treatment, there is a demand for mechanically stronger implants. Despite the existence of several studies showing the clinical success of narrow diameter implants, most of them are based on pure titanium (cpTi) alloys.
Tatiana de Andrade Sabino +6 more
doaj +1 more source
Stress distribution of restorations in external cervical root resorption under occlusal and traumatic loads: a finite element analysis [PDF]
Objectives This study analyzed the stress distribution in a maxillary central incisor with external cervical resorptive defect restored with different restorative materials under normal masticatory and traumatic loading conditions using finite element ...
Padmapriya Ramanujam +5 more
doaj +1 more source
FEM and BEM Stress Analysis of Mandibular Bone Surrounding a Dental Implant [PDF]
In the present work the structural behaviour of a mandible with a dental implant, considering a unilateral occlusion, is numerically analysed by means of the Finite Element Method (FEM) and the Boundary Element Method (BEM). The mandible, whose CAD model was obtained by computer tomography scans, is considered as completely edentulous and only modelled
Perrella M +2 more
openaire +7 more sources
Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the ...
Aaron Yu-Jen Wu +5 more
doaj +1 more source
Influence of prefabricated post screw head design on the stress pattern in the core and crown. Finite element stress analysis study [PDF]
Objectives: This study evaluated the influence of dental post head design on the stress distribution in the core and crown structure as an in vitro study.
Abdulsalam R Al-Zahawi
core +1 more source
Objectives: To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. Material and Methods: An online literature search was performed on MEDLINE and EMBASE databases
Julius Maminskas +4 more
doaj +1 more source
An Analysis of “Stress Factors” among Dental Students
Abstract Background:The objective of the study was to assess the perceived stress and its severity, sources, and determinants among a group of dental students belonging to different universities in Saudi Arabia.Methods: In this cross-sectional study, the perceived stress and its severity, sources and demographic variables were studied in 677 ...
Faisal Suliman Alhedyan +4 more
openaire +1 more source
Stress Analysis of an Endosseus Dental Implant by BEM and FEM [PDF]
In this work the Boundary Element Method (BEM) and the Finite Element Method (FEM) have been used for an elastic-static analysis of both a Branemark dental implant and a generic conic threaded implant, modelled either in the complete mandible or in a mandibular segment, under axial and lateral loading conditions. Two different hypotheses are considered
CITARELLA, Roberto Guglielmo +3 more
openaire +5 more sources