Three dimensional analysis on the deformation of the master cast during maxillary complete denture fabrication [PDF]
This study aimed to assess the changes in maxillary master casts that occur during complete denture fabrication, focusing on a compression molded denture. Digital merging techniques were used to measure the changes in 12 maxillary master casts at various
Junghyun Nam +4 more
doaj +3 more sources
Rehabilitation of a Hemimandibulectomy Patient with an Overlay Denture: A Case Report [PDF]
Prosthetic rehabilitation of hemimandibulectomy patient, with an overlay denture, restores missing skeletal, dental structures, muscle imbalance, maxillomandibular relationship and occlusion.
Siva Prakash Dhanaraj, H Annapoorni
doaj +3 more sources
Stress Distribution Pattern in Mandibular Overdenture Designs Supported by Three Dental Implants: A 3D Finite Element Analysis [PDF]
Objectives The purpose of this study was to assess the implant‐supported overdenture stress distribution pattern in cancellous and cortical bone, dental implants, and prosthetic components, and its displacement by using finite element analysis (FEA ...
Negin Aminianpour +4 more
doaj +3 more sources
Interim three-dimensional printed overlay prosthesis for an adolescent patient with oligodontia
Oligodontia is a developmental anomaly which represents the congenital absence of more than six teeth in primary, permanent, or both dentitions and may or may not be associated with a syndrome.
Deepa Mukkai Krishnamurthy +2 more
doaj +2 more sources
This clinical report describes prosthetic rehabilitation of posterior open bite relationship in a patient with several missing teeth and skeletal Class III malocclusion.
Saeid Nosouhian +2 more
doaj +2 more sources
Suitability and Trueness of the Removable Partial Denture Framework Fabricating by Polyether Ether Ketone with CAD-CAM Technology. [PDF]
The object of the study was to evaluate the suitability and trueness of the removable partial denture (RPD) framework fabricated by polyether ether ketone (PEEK) with the CAD-CAM technology in vitro.
Zhao K, Wu S, Qian C, Sun J.
europepmc +2 more sources
Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases [PDF]
Background: Digital technology has been introduced in prosthodontics, and it has been widely used in denture duplication instead of a conventional denture duplication technique. However, research comparing different denture duplication techniques and how
Abdel-Naser M. Emam +5 more
doaj +2 more sources
Mandibular overdenture retained by telescopic crowns and ball attachments on semierupted premolars
This clinical report describes the oral rehabilitation with a mandibular overdenture retained by telescopic crowns and ball attachments on semierupted permanent teeth with a 5-year follow-up.
Elisa C Knebel +2 more
doaj +1 more source
Overdenture in terms of preparation and restoration of supporting teeth: Review report [PDF]
nema
Ilić Dragan V. +2 more
doaj +1 more source
A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report [PDF]
To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening
Hyunsuk Choi, Sohee Kang
doaj +1 more source

