Results 11 to 20 of about 188,180 (347)
To investigate the fatigue behavior of cast and laser‐sintered cobalt‐chromium (CoCr) and polyetheretherketone (PEEK) material for a removable partial denture (RPD) clasps.
Jenny L. Zheng+4 more
semanticscholar +2 more sources
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture. The purpose of this study is to assess the mechanical performance of graphene-based polymer (GBP) and polyether-ether-ketone (PEEK) materials as clasp ...
Mostafa Omran Hussein
semanticscholar +1 more source
PURPOSE To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on different retentive areas.
Jenny L. Zheng+4 more
semanticscholar +1 more source
Retention and support are needed for removable partial denture stability. The stability can be achieved by clasps, occlusal and cingulum rests on healthy abutment teeth.
Fahad Hussain Alhamoudi+7 more
doaj +1 more source
The removable partial denture equation [PDF]
This article describes the benefits and risks of providing RPDs. It emphasises the importance of co-operation between the dental team and patient to ensure that the balance of this 'equation' is in the patient's favour.
J C Davenport+4 more
openaire +3 more sources
Abstract Objectives To compare the marginal and internal fit and fracture resistance of three‐unit provisional fixed dental prostheses (FDPs) fabricated by additive, subtractive, and conventional methods. Material and Methods Eighty 3‐unit FDPs were fabricated on metal dies of the maxillary right second premolar and second molar by four different ...
Mehran Falahchai+4 more
wiley +1 more source
A Digital Workflow for the Fabrication of a Milled Removable Partial Denture
Complete dentures fabricated with the additive or subtractive method have been widely used and proven to be clinically acceptable. However, fabrication of removable partial dentures (RPDs) using computer-aided design and computer-aided manufacturing is ...
Xing-Yu Piao+3 more
semanticscholar +1 more source
This study aimed to compare strain around implants used as abutments for removable partial dentures with wrought wires and fixed partial dentures with ball attachments and fixed dentures with posterior cantilever.
Roodabeh Koodaryan+4 more
doaj +1 more source
PURPOSE This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and ...
Atsushi Takaichi+7 more
semanticscholar +1 more source
Dental management before radiotherapy of the head and neck region: 4‐year single‐center experience
Abstract Objective To review our experience with a standardized dental management approach in patients with planned radiotherapy of the head and neck region based on preradiation and follow‐up data. Material and Methods Records of patients who underwent radiotherapy between June 2016 and November 2020 were reviewed.
Lea Hoffmann+5 more
wiley +1 more source