Results 1 to 10 of about 23,946 (291)
Design of complete denture reinforced with metal base [PDF]
Introduction. Complete denture reinforced with metal bases is fabricated in cases of fracture risk as well as in selected patients with neuromuscular disorders.
Poštić Srđan D.
doaj +3 more sources
Designing for Safety: Implications of a Fifteen Year Review of Swallowed and Aspirated Dentures [PDF]
Objectives: Dentures are worn by around 20% of the population, yet if they become displaced they may enter the gastrointestinal or respiratory system, sometimes with grave consequences.
Samuel J. W. Kent +2 more
doaj +6 more sources
Expert consensus on digital restoration of complete dentures [PDF]
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control
Yue Feng +27 more
doaj +2 more sources
APPLICATION OF DIGITAL TECHNOLOGIES FOR COMPLETE DENTURES [PDF]
Introduction: The daily practice shows that the patients prefer treatments that require fewer visits and low cost. The technology of conventional complete dentures follows several subsequent stages – clinical and laboratory.
Yordanka Donkova +2 more
doaj +1 more source
Dentistry 4.0 concept in designing and manufacturing removable partial denture frameworks [PDF]
nema
Stamenković Dejan +2 more
doaj +1 more source
Background: The aim of this study was to evaluate the retention of implant-supported overdentures with different attachment systems. Materials and Methods: In this in vitro study edentulous model with 2 Straumann implant in symphyseal region was used to ...
Farahnaz Nejatidanesh +3 more
doaj +1 more source
Background/aim Clinical studies comparing the retention values of computer-aided design/computer-aided manufacturing (CAD/CAM) denture bases with those of conventionally processed denture bases are lacking.
Shady M. EL Naggar +4 more
doaj +1 more source
Measurement of the accuracy of dental working casts using a coordinate measuring machine [PDF]
Background/Aim: Dental impressions present a negative imprint of intraoral tissues of a patient which is, by pouring in gypsum, transferred extraorally on the working cast.
Potran Michal +5 more
doaj +1 more source
Removable partial denture design in the general dental practice II.
Professional, legal and ethical guidelines and rules guide the duties and responsibilities of dentists in relation to patient care, including the fabrication of removable partial dentures with cast clasp retained metal framework. The aim of our study was
Márta Radnai +4 more
doaj +1 more source

