Results 191 to 200 of about 1,253,282 (331)
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim +6 more
wiley +1 more source
Single-shot extended-depth-of-field fourier light field microscopy enabled by a distorted grating. [PDF]
Huang J +7 more
europepmc +1 more source
Extended the depth of field and zoom microscope with varifocal lens. [PDF]
Chen Y, Liu H, Zhou Y, Kuang FL, Li L.
europepmc +1 more source
Oxygen‐tunnel (OT) indium tin oxide (ITO) vertical channel transistors (VCTs) enable reliable, high‐density gain‐cell memory for monolithic 3D integration. A sandwiched SiN/SiO2/SiN OT stack selectively regulates oxygen transport, suppressing parasitic electrode oxidation while stabilizing channel oxygen vacancies, thereby suppressing carrier injection
Hyeonho Gu +17 more
wiley +1 more source
Deep-learning endomicroscope with large field-of-view and depth-of-field for real-time in vivo imaging of epithelial cancer hallmarks. [PDF]
Hou H +15 more
europepmc +1 more source
E2E-BPF microscope: extended depth-of-field microscopy using learning-based implementation of binary phase filter and image deconvolution. [PDF]
Seong B +7 more
europepmc +1 more source
Receptor‐Free Identification of Toxic Gases Enabled by Hygroscopic Aqueous Salt Films
Water as a gas sensor coating sounds impossible—until it stops evaporating. Here, hygroscopic salt solutions (LiCl, LiBr, H3PO4) form non‐drying aqueous films on CNT chemiresistors under ambient air. Gases partition into these liquid layers, sometimes transforming into water, and generate salt‐specific resistance fingerprints across a four‐channel ...
Seongwoo Lee +5 more
wiley +1 more source
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe,
Minseong Chae +27 more
wiley +1 more source
Clinical Performance After Implantation of a New Purely Refractive Extended Depth of Field Intraocular Lens in Cataract Patients. [PDF]
Auffarth GU +6 more
europepmc +1 more source

