Results 221 to 230 of about 1,416 (265)
Some of the next articles are maybe not open access.

Desiccant aging and its effects on desiccant cooling system performance

Applied Thermal Engineering, 1996
Desiccants used for the purpose of space conditioning or enthalpy transfer can be subjected to hundreds of thousands of adsorption/regeneration cycles over their useful life. Studying the loss of a desiccant's equilibrium water adsorption capacity after exposure to thermal cycling is a common method for quantifying desiccant aging. Since isotherm shape
William A. Belding   +2 more
openaire   +1 more source

Progress in selecting desiccant and dehumidifier for liquid desiccant cooling system

Energy and Buildings, 2012
Abstract Liquid desiccant cooling system (LDCS) is an alternative air-conditioning system with good energy-saving potential. Dehumidification performance is the key part of LDCS; while desiccant variety and dehumidifier influence the dehumidification performance.
Xiu-Wei Li   +3 more
openaire   +1 more source

Sorption equilibrium of a solid desiccant felt and the effect of sorption properties on a cooled-bed desiccant cooling system

Journal of Heat Recovery Systems, 1986
Abstract The equilibrium sorption isotherms of a silica gel matrix manufactured in the form of a desiccant felt are experimentally determined as a function of temperature and relative humidity. Using the data, the differential heat of sorption and the integral heat of wetting are calculated. These results then are used as property data in a numerical
S. Dini, W.M. Worek
openaire   +1 more source

Feasible study of a self-cooled solid desiccant cooling system based on desiccant coated heat exchanger

Applied Thermal Engineering, 2013
Abstract Solid desiccant cooling technology has become a research focus for its features of energy-saving and eco-friendly. However, widely adopted rotary desiccant wheel cooling system can't realize inner-cooling dehumidification process. In this paper, a novel self-cooled solid desiccant cooling system (SCDHE) is developed by integrating desiccant ...
T.S. Ge, Y.J. Dai, R.Z. Wang, Y. Li
openaire   +1 more source

Performance of Cross-Cooled Desiccant Dehumidifiers

Journal of Solar Energy Engineering, 1983
A cross-cooled silica gel desiccant dehumidifier model was designed, built, and tested. The performance of the unit was studied as a function of the inlet process stream dew point, process stream and cooling stream flow rates, and regeneration stream temperature and dew point. The tests were also simulated by a computer program and were compared to the
V. C. Mei, Z. Lavan
openaire   +1 more source

A hybrid solar desiccant cooling system

Solar Energy, 1985
Alternative methods of providing cooling using lower-grade energy have been investigated. This paper considers a cycle which combines indirect evaporative cooling with a dehumidifier to meet latent loads and a vapour compression refrigeration unit to meet sensible load.
J.C. Sheridan, J.W. Mitchell
openaire   +1 more source

Prototype test of a desiccant cooling system

Journal of the Chinese Institute of Engineers, 1989
Abstract A prototype of a desiccant cooling system was designed and tested in the present study for the development of basic design techniques and the assessment of feasibility and market potential in Taiwan. Test results are presented to show the system performance of the desiccant cooling system.
Bin‐Juing Huang, In‐Fan Liao
openaire   +1 more source

Review on Recent development in Desiccant Cooling

International Journal of Energy Resources Applications, 2022
Due to its sustainable cooling design and inexpensive operation, desiccant based dehumidification and cooling systems have been popular in recent years for humid areas. In general, the desiccant cooling used in conjunction with evaporative cooling as two separate types of configurations according to direct or indirect cooling.
openaire   +1 more source

Performance of a Solar Desiccant Cooling System

Journal of Solar Energy Engineering, 1988
A solar desiccant cooling system was operated at the Solar Energy Applications Laboratory, Colorado State University, throughout the 1986 summer. The system comprises an American Solar King fresh air heating/desiccant evaporative cooling unit, a Sunmaster evacuated tube solar collector, hot water solar storage tank, auxiliary electric boiler, controls,
George O. G. Lo¨f   +2 more
openaire   +1 more source

Performance Analysis of a Desiccant Rotor for Rotational Period in a Desiccant Cooling System

Transactions of the Korean Society of Mechanical Engineers B, 2012
The performance simulation of a desiccant rotor, which is a core component of a desiccant cooling system, was conducted on the basis of a theoretical solution of the heat and mass transfer process in the rotor. The simulation model was validated by comparing simulation results with experimental data; reasonable agreement was observed. The effect of the
Chang-Hun Pi   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy