Results 1 to 10 of about 116,701 (118)

Nanoscale Estimation of Coating Thickness on Substrates via Standardless BSE Detector Calibration [PDF]

open access: yesNanomaterials, 2020
The thickness of electron transparent samples can be measured in an electron microscope using several imaging techniques like electron energy loss spectroscopy (EELS) or quantitative scanning transmission electron microscopy (STEM).
Radim Skoupy   +2 more
doaj   +2 more sources

Efficiency calibration of a well-type HPGe detector using experimental and Monte Carlo simulation techniques [PDF]

open access: yesNuclear Technology and Radiation Protection, 2020
Well-type high-purity germanium detectors are well suited for the analysis of small samples, as they combine high detection efficiency with low background radiation. The well geometry however makes efficiency calibration more difficult than that
Dalaka Ekaterini   +3 more
doaj   +1 more source

Efficient Iterative Calibration on the Grid using iLCDirac [PDF]

open access: yesEPJ Web of Conferences, 2020
Software tools for detector optimization studies for future experiments need to be efficient and reliable. One important ingredient of the detector design optimization concerns the calorimeter system.
Viazlo Oleksandr, Sailer André
doaj   +1 more source

A mathematical model of semiconductor detector gamma-efficiency calibration for rectangular cuboid (brick-shape) sources [PDF]

open access: yesNuclear Technology and Radiation Protection, 2018
Rectangular cuboid (rectangular parallelepiped), i. e., brick-shape sources are not really common in general gamma-spectrometry practice with semiconductor detectors, where axially symmetrical sources prevail.
Mihaljević Nikola N.   +3 more
doaj   +1 more source

LIDAL, a Time-of-Flight Radiation Detector for the International Space Station: Description and Ground Calibration

open access: yesSensors, 2023
LIDAL (Light Ion Detector for ALTEA, Anomalous Long-Term Effects on Astronauts) is a radiation detector designed to measure the flux, the energy spectra and, for the first time, the time-of-flight of ions in a space habitat.
Giulia Romoli   +23 more
doaj   +1 more source

Calibration of Calorimetric Measurement in a Liquid Argon Time Projection Chamber

open access: yesInstruments, 2020
The liquid argon time projection chamber provides high-resolution event images and excellent calorimetric resolution for studying neutrino physics and searching for beyond-standard-model physics. In this article, we review the main physics processes that
Tingjun Yang
doaj   +1 more source

An end-to-end in-flight calibration of Mini-EUSO detector [PDF]

open access: yesEPJ Web of Conferences, 2023
Mini-EUSO is a wide Field-of-View (FoV, 44°) telescope currently in operation from a nadir-facing UV-transparent window in the Russian Zvezda module on the International Space Station (ISS).
Miyamoto Hiroko   +54 more
doaj   +1 more source

Analysis and Correction of Polarization Response Calibration Error of Limb Atmosphere Ultraviolet Hyperspectral Detector

open access: yesSensors, 2022
A UV hyperspectral instrument was designed with a polarization measurement channel for real-time in-orbit polarization correction to reduce the influence of polarization on the detection accuracy of atmospheric radiation.
Haochen Li   +7 more
doaj   +1 more source

Modeling of germanium detector and its sourceless calibration [PDF]

open access: yesNuclear Technology and Radiation Protection, 2008
The paper describes the procedure of adapting a coaxial high-precision germanium detector to a device with numerical calibration. The procedure includes the determination of detector dimensions and establishing the corresponding model of the system.
Steljić Milijana   +2 more
doaj   +1 more source

MCORD - MPD Cosmic Ray Detector a new features [PDF]

open access: yesEPJ Web of Conferences, 2019
The main detector system at the Nuclotron-based Ion Collider fAcility (NICA) located in Dubna, Russia is the Multi-Purpose Detector (MPD). For better calibration reason, the MPD needs an additional trigger system for an off-beam calibration of MPD sub ...
Bielewicz M.   +25 more
doaj   +1 more source