Dewatering Preloading Test and Ground Subsidence in a Project
Ground subsidence is one of the main geological hazards in Shanghai. The ground subsidence is caused by pumping groundwater greatly. In the past, studies of ground subsidence in Shanghai were mostly taken for the ground subsidence caused by pumping confined water in Puxi.
Yong Mou Zhang, Jian Chang Zhao
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Role of geotextiles pore size distribution in dewatering tests
Geosynthetics International, 2020For geotextile tube dewatering applications, several researchers have used one-dimensional dewatering tests to estimate soil piping and sediment retention by correlating geotextile pore openings (A...
N. Fatema, S. Bhatia
openaire +1 more source
Testing of an Enhanced Brine Dewatering System
40th International Conference on Environmental Systems, 2010Water recovery is essential for long-duration space exploration transit and outpost missions. Primary stage wastewater recovery systems partially satisfy this need, and generate concentrated wastewater brines that are unusable without further processing. The Enhanced Brine Dewatering System (EBDS) is being developed to allow nearly complete recovery of
Ross Remiker +3 more
openaire +1 more source
Testing procedures to assess the viability of dewatering with geotextile tubes
Geotextiles and Geomembranes, 2002Abstract Geotextile tubes are finding increasing market acceptance for dewatering high water content materials. The success of this application depends on the filtration compatibility between the high water content materials and the geotextiles used to make the tubes. In this paper, 26 pressure filtration tests using four woven geotextiles of various
Horace K Moo-Young +2 more
openaire +1 more source
QUANTITATIVE TEST OF THE EFFICIENCY OF DEWATERING FLUIDS
Anti-Corrosion Manual, 1972Introduction In engineering it is often necessary to remove free water or surface moisture films from metal components and structures prior to the application of some finishing treatment. In many branches of production engineering, metal fabrications may require temporary rust prevention protection between processes, and this is frequently coupled with
openaire +1 more source
Field Test of Geotextile Tube for Dewatering Dairy Lagoon Sludge
2004, Ottawa, Canada August 1 - 4, 2004, 2004A geotextile filtration tube was used to dewater lagoon solids from a first stage dairy lagoon. Slurry was pumped from the lagoon into the tube with filtered liquid seeping from the tube and returning to the lagoon. The experiment was repeated three times.
null John W. Worley +2 more
openaire +1 more source
Pilot-scale testing of novel fine-particle dewatering aids
Mining, Metallurgy & Exploration, 2003Novel dewatering aids were tested on various coal samples from the United States and Canada. Both laboratory and pilot-scale filtration experiments were performed on the samples. The reagents substantially improved the dewatering kinetics and reduced the cake moistures.
R.-H. Yoon +4 more
openaire +1 more source
Test Study on Dewatering Effect of Sewage Sludge by Vacuum Method
Advanced Materials Research, 2012The aeration-vacuum dewatering method is a new kind of solid-liquid separate technique. The filter clogging problem in the routine vacuum dewatering procedure of sludge can be solved by the method. This method is used to dewater the sewage sludge in this paper.
Yu Feng Gao +3 more
openaire +1 more source
A Comparison of Test Methods Adopted for Assessing Geotextile Tube Dewatering Performance
Geo-Frontiers 2011, 2011Geotextile tubes have successfully been used by virtually every industry today to dewater a variety of sediments, slurries, by-products, and wastes. Despite this, the dewatering industry currently lacks uniformity in regards to establishing testing standards and assessing dewatering performance.
M. D. Grzelak +4 more
openaire +1 more source