Results 101 to 110 of about 10,066 (215)

DVC strategy with MPPT for a DFIG-based SeaFlow variable-speed marine current turbine

open access: yesRevue des Énergies Renouvelables
The integration of marine current turbines is a keystone of the global race toward renewable energy, and tidal currents, in particular, offer higher predictability and energy density, providing a reliable source of clean power.
Abdelkader Garmat   +3 more
doaj   +1 more source

Overview of HVRT technical measures for DFIG

open access: yesIOP Conference Series: Earth and Environmental Science, 2017
A With the rapid increase of the proportion of double-fed induction wind turbines generator (DFIG), higher requirements are proposed for the continuous operation ability under external power grid failure. The paper first analysed the transient process of DFIG in cases of power grid voltage surge, proposed the related standard requirements for high ...
openaire   +1 more source

Study on Fault Current of DFIG during Slight Fault Condition [PDF]

open access: yes, 2013
In order to ensure the safety of DFIG when severe fault happens, crowbar protection is adopted. But during slight fault condition, the crowbar protection will not trip, and the DFIG is still excited by AC-DC-AC converter.
Kong, Xiangping   +3 more
core   +1 more source

A novel hybrid interlinking transformer-integrated DFIG wind power and energy storage system with flexible control strategy

open access: yesInternational Journal of Electrical Power & Energy Systems
Double-fed induction generator (DFIG) based wind turbine generator (WTG) demonstrates pronounced sensitivity to the abnormal grid voltages, such as sag, swell or harmonic, which can precipitate disconnections from the power grid due to fault ride-through
Jinmu Lai   +6 more
doaj   +1 more source

DFIG control: A fuzzy approach [PDF]

open access: yesInternational Journal of ADVANCED AND APPLIED SCIENCES, 2019
openaire   +1 more source

Key Technology in the Design of Double-fed Induction Generator for High Power Wind Turbine

open access: yesKongzhi Yu Xinxi Jishu, 2013
Wind driven DFIG (double fed induction generator) is the mainstream model of grid-connected high power wind turbine and DFIG is the key part that influence the performance and reliability of wind turbine.
LI Jinze, WANG Jianliang
doaj  

The Simulation of DFIG Grid Side Converter

open access: yes, 2017
Firstly,DFIG basic structure of grid side converter was analyzed according to basic principles of voltage converter, and a mathematical model of grid side converter was established in the three-phase stationary coordinate system and the two-phase rotating coordinate system respectively.
LU Yan-Ling, LU Jian-qiang, BAO Jie
openaire   +1 more source

Control Strategy of Fault-ride-through-based on Variable Damper in Doubly-fed Induction Generator Wind Power Generation System

open access: yes工程科学与技术, 2018
In order to solve the problems of rotor over-current and fault-ride-through (FRT) and improve the performance of the doubly-fed induction generator wind power generation system (DFIG-WPGS), the based on variable damper (BVD) strategy was proposed.
Junli ZHANG, Yuanmin ZHANG, Yuren LI
doaj  

Grid Voltage Unbalance and The Integration of DFIG’s

open access: yes, 2013
Double-fed induction generators (DFIG’s) became the predominant generator installed for wind generation applications in the mid 1990’s. Issues pertaining to the operation and control of DFIG’s subsequently became apparent, particularly in weak areas of the grid network.
openaire   +2 more sources

Home - About - Disclaimer - Privacy