Results 101 to 110 of about 10,066 (215)
DVC strategy with MPPT for a DFIG-based SeaFlow variable-speed marine current turbine
The integration of marine current turbines is a keystone of the global race toward renewable energy, and tidal currents, in particular, offer higher predictability and energy density, providing a reliable source of clean power.
Abdelkader Garmat +3 more
doaj +1 more source
Overview of HVRT technical measures for DFIG
A With the rapid increase of the proportion of double-fed induction wind turbines generator (DFIG), higher requirements are proposed for the continuous operation ability under external power grid failure. The paper first analysed the transient process of DFIG in cases of power grid voltage surge, proposed the related standard requirements for high ...
openaire +1 more source
Study on Fault Current of DFIG during Slight Fault Condition [PDF]
In order to ensure the safety of DFIG when severe fault happens, crowbar protection is adopted. But during slight fault condition, the crowbar protection will not trip, and the DFIG is still excited by AC-DC-AC converter.
Kong, Xiangping +3 more
core +1 more source
Double-fed induction generator (DFIG) based wind turbine generator (WTG) demonstrates pronounced sensitivity to the abnormal grid voltages, such as sag, swell or harmonic, which can precipitate disconnections from the power grid due to fault ride-through
Jinmu Lai +6 more
doaj +1 more source
DFIG control: A fuzzy approach [PDF]
openaire +1 more source
Key Technology in the Design of Double-fed Induction Generator for High Power Wind Turbine
Wind driven DFIG (double fed induction generator) is the mainstream model of grid-connected high power wind turbine and DFIG is the key part that influence the performance and reliability of wind turbine.
LI Jinze, WANG Jianliang
doaj
The Simulation of DFIG Grid Side Converter
Firstly,DFIG basic structure of grid side converter was analyzed according to basic principles of voltage converter, and a mathematical model of grid side converter was established in the three-phase stationary coordinate system and the two-phase rotating coordinate system respectively.
LU Yan-Ling, LU Jian-qiang, BAO Jie
openaire +1 more source
In order to solve the problems of rotor over-current and fault-ride-through (FRT) and improve the performance of the doubly-fed induction generator wind power generation system (DFIG-WPGS), the based on variable damper (BVD) strategy was proposed.
Junli ZHANG, Yuanmin ZHANG, Yuren LI
doaj
Grid Voltage Unbalance and The Integration of DFIG’s
Double-fed induction generators (DFIG’s) became the predominant generator installed for wind generation applications in the mid 1990’s. Issues pertaining to the operation and control of DFIG’s subsequently became apparent, particularly in weak areas of the grid network.
openaire +2 more sources
New orientation technique of aligned D-Q reference frame for controlling doubly-fed induction generators. [PDF]
Elgamasy MM +4 more