Results 81 to 90 of about 35,251 (193)
ABSTRACT The condition assessment of oil–paper insulation is critical for oil–immersed power transformers, which are fundamental to the reliability of modern power systems. The primary limitation of traditional transformer ageing assessment lies in its macroscopic, whole‐unit approach, which fails to account for the localised effects of nonuniform ...
Mingze Zhang +7 more
wiley +1 more source
Dissolved gas analysis (DGA) of transformer oil is considered to be the utmost reliable condition monitoring technique currently used to detect incipient faults within power transformers.
Ahmed Abu-Siada
doaj +1 more source
1/4 left side view of a Howard DGA, a civilian plane, on the ground.https://corescholar.libraries.wright.edu/special_ms344_photographs/1345/thumbnail ...
core +1 more source
ABSTRACT The complex diffusion of characteristic gases within oil‐immersed transformers significantly influences the timeliness between the fault occurrence and gas detection. So far, the gas transport processes and spatio‐temporal distributions remain inadequately understood.
Chunpeng Li +7 more
wiley +1 more source
ABSTRACT Dissolved gas analysis (DGA), widely used for fault diagnosis, can be significantly influenced by the presence of oxygen. Oxygen not only accelerates fluid degradation but also alters the type and concentration of fault gases generated, potentially leading to misinterpretation of transformer conditions if conventional DGA models are applied ...
Moïse Agouassi +4 more
wiley +1 more source
ABSTRACT With the advancement of the ‘carbon peaking and carbon neutrality’ targets and the construction of new power systems, the operating environment of power equipment is becoming increasingly complex, rendering traditional operation and maintenance strategies insufficient to meet the demands of safe and stable grid operation.
Hui Song +5 more
wiley +1 more source
A right side view of a Howard DGA-3, a civilian plane, on the ground.https://corescholar.libraries.wright.edu/special_ms344_photographs/1346/thumbnail ...
core +1 more source
Phân tích khí hòa tan trong dầu cách điện là phương pháp phổ biến để theo dõi tình trạng máy biến áp (MBA) ngâm dầu. Các tổ chức tiêu chuẩn quốc tế và các nhà nghiên cứu đã phát triển nhiều phương pháp như: phương pháp tỷ lệ Doernenburg, tỷ lệ Roger, tỷ ...
Nguyễn Văn Ngà +5 more
doaj
ABSTRACT Oil‐immersed power equipment is a critical component for energy transmission and secure operation of modern power grids. The ageing of oil–paper insulation under combined electrical, thermal and mechanical stresses directly affects equipment lifetime and system reliability. This paper presents a comprehensive review of the ageing behaviour and
Ruijin Liao +6 more
wiley +1 more source
D-glyceric aciduria due to GLYCTK mutation: Disease or non-disease?
D-glyceric aciduria (DGA) is caused by D-glycerate-2-kinase deficiency due to biallelic pathogenic variants in GLYCTK. It is associated with variable neurological symptoms.
Sandra D.K. Kingma +6 more
doaj +1 more source

