Results 261 to 270 of about 12,449,625 (324)
Expanding the Concept of Diagnostic Reference Levels to Noise and Dose Reference Levels in CT
OBJECTIVE. Diagnostic reference levels were developed as guidance for radiation dose in medical imaging and, by inference, diagnostic quality. The objective of this work was to expand the concept of diagnostic reference levels to explicitly include noise of CT examinations to simultaneously target both dose and quality through corresponding reference ...
Francesco Ria +2 more
exaly +4 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
American Journal of Roentgenology, 2015
W1 demand [4]. Dose limits apply to occupational and public exposure, not to exposure of patients (medical exposure), because limits may compromise patient care. Diagnostic reference levels are used as a trigger to identify those facilities using unusually high doses in a specified radiologic procedure, for which optimization actions are needed.
Jenia Vassileva, Madan M Rehani
exaly +3 more sources
W1 demand [4]. Dose limits apply to occupational and public exposure, not to exposure of patients (medical exposure), because limits may compromise patient care. Diagnostic reference levels are used as a trigger to identify those facilities using unusually high doses in a specified radiologic procedure, for which optimization actions are needed.
Jenia Vassileva, Madan M Rehani
exaly +3 more sources
Mammography Diagnostic Reference Levels (DRLs) in Ghana
Radiography, 2021Diagnostic Reference Levels (DRLs) are essential for optimisation in mammography. A local DRL for screen-film mammography has been established in Ghana but none exists for the digital mammography systems. Furthermore, technological advancement is phasing out the use of screen-film mammography and replacing it with digital mammography systems.
Klenam Dzefi-Tettey, Seth Angmorterh
exaly +3 more sources
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Pediatric CT Examinations.
Radiology, 2021Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry.
K. Kanal +11 more
semanticscholar +1 more source
Establishing local diagnostic reference levels for adult computed tomography in Morocco
Radioprotection - Revue de la Societé Francaise de Radioprotection, 2022In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed.
M. El Mansouri +4 more
semanticscholar +1 more source
Local Diagnostic Reference Levels for Typical Radiographic Procedures [PDF]
PurposeTo establish local diagnostic reference levels (DRL) for typical radiographic examinations in a fully digital imaging institution.MethodsThe initial survey included 6 standard radiographic projections performed in 19 computed radiography (CR) and ...
Elena Tonkopi
exaly +2 more sources
National diagnostic reference levels: What they are, why we need them and what’s next
Journal of Medical Imaging and Radiation Oncology, 2022Diagnostic reference levels (DRLs) are an optimisation tool for medical imaging procedures using ionising radiation. They give an indication of the expected radiation dose received by an average‐sized patient undergoing a given imaging procedure ...
P. Thomas
semanticscholar +1 more source
A Review of Diagnostic Reference Levels in Computed Tomography
Current Medical Imaging Formerly Current Medical Imaging Reviews, 2022: Computed Tomography (CT) scanning generates 3-D images of the inside structures of the body by delivering a comparative radiation dose to the patient. This requires great concern of optimization via establishing Diagnostic Reference Level (DRL). DRL values can be estimated based on reference patient percentiles (such as 90th, 75th, and 50th) dose ...
Ilker Ozsahin +2 more
openaire +2 more sources
Physica medica (Testo stampato), 2022
INTRODUCTION The paediatric radiation dose has never been studied in Sri Lanka, nor has a national diagnostic reference level (NDRL) established. Therefore, the primary aim of this study was to propose diagnostic reference levels (DRL) and achievable ...
D. Satharasinghe +4 more
semanticscholar +1 more source
INTRODUCTION The paediatric radiation dose has never been studied in Sri Lanka, nor has a national diagnostic reference level (NDRL) established. Therefore, the primary aim of this study was to propose diagnostic reference levels (DRL) and achievable ...
D. Satharasinghe +4 more
semanticscholar +1 more source
Local Diagnostic Reference Levels in Interventional Radiology
Journal of Medical Imaging and Radiation Sciences, 2020Interventional cardiology procedures, during which live images are acquired, involve exposure to x-rays. The use of fluoroscopy can cause high radiation doses to patients and operators because of the prolonged duration of x-ray emission. For this reason, special attention and constant vigilance represent challenges for commissions and groups of experts
Imane, Ou-Saada +4 more
openaire +2 more sources

