Results 181 to 190 of about 1,706,764 (337)

Commissioning evaluation of a deviceless 4DCT scanner

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The utilization of four‐dimensional computed tomography (4DCT) for radiation therapy has not seen major advances to the method of data binning since shortly after inception. Recently there is increased interest in the utilization of an alternative binning method rather than more established techniques.
Hunter Tillery   +2 more
wiley   +1 more source

Architected Lattices with a Topological Transition

open access: yesAdvanced Engineering Materials, EarlyView., 2023
This article develops topological metamaterials showing multidirectional two‐step deformation under compression by embedding contact‐enabled topological mechanisms into lattice structures. Experiments on 3D‐printed 2D and 3D lattices and finite element simulations are conducted to demonstrate the working principle of the topological metamaterials.
Shivam Agarwal, Lihua Jin
wiley   +1 more source

DIAMETER EFFECT I

open access: green, 1953
John G. Kirkwood, William W. Wood
openalex   +2 more sources

Assessing the rigidity of thermoplastic masks for head immobilization effectiveness in stereotactic radiosurgery

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study compared three Brainlab thermoplastic masks—Cranial 4pi basic, stereotactic (Close Mask V2), and open‐face—to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system.
Iris Pasion Apale   +2 more
wiley   +1 more source

Investigation of the Uniformity of Gel Shrinkage by Imaging Tracer Particles Using X‐Ray Microtomography

open access: yesAdvanced Engineering Materials, EarlyView., 2023
A novel method for tracking structural changes in gels using widely accessible microcomputed tomography is presented and validated for various hydro‐, alco‐, and aerogels. The core idea of the method is to track positions of micrometer‐sized tracer particles entrapped in the gel and relate them to the density of the gel network.
Anja Hajnal   +3 more
wiley   +1 more source

Characterization of a prototype rapid kilovoltage x‐ray image guidance system designed for a linear accelerator radiation therapy unit

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault   +9 more
wiley   +1 more source

Ultrasound-based incidence of coarctation of the aorta in true and false positive fetuses. [PDF]

open access: yesSci Rep
Chen G   +10 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy