Results 121 to 130 of about 441 (148)
Some of the next articles are maybe not open access.

Influence of the order of diattenuator, retarder, and polarizer in polar decomposition of Mueller matrices

Optics Letters, 2004
Polar decomposition consists of representing an arbitrary Mueller matrix with a product of three simpler matrices, but, since these matrices do not commute, the result depends on the order in which they are multiplied. We show that the six possible decompositions can be classified into two families and that one of these families always leads to ...
Jérôme, Morio, François, Goudail
openaire   +2 more sources

Mueller Matrix Polarimeter with Diattenuation Error Calibration Approach

2015
A calibration algorithm for the Mueller matrix dual-rotating retarder polarimeter is presented. The Mueller matrix dual-rotating retarder polarimeter is composed by two rotating retarders and two fixed polarizers with the final purpose of retrieving the polarization properties of a sample.
Kaustav Bhattacharyya   +2 more
openaire   +1 more source

Polarization adaptive optics for diattenuation aberration correction

Optica Imaging Congress 2024 (3D, AOMS, COSI, ISA, pcAOP)
We propose the use of optical skyrmions as a way to probe an optical system and provide metrics that characterise the performance of a polarisation adaptive optics system in the presence of diattenuation aberrations.
Yifei Ma   +6 more
openaire   +1 more source

Simple polarization measurement of a depolarizing retarder with diattenuation

Applied Optics
A method is proposed to measure the polarimetric parameters of a depolarizing retarder with diattenuation (DRD). The retardance is expressed as a tangent function that recovers its correct sign as opposed to the usual calculation of the retardance through a cosine function. The depolarizing parameters of a pure depolarizer, normally
Efren Ulloa-Peña   +4 more
openaire   +1 more source

Transmittance and Diattenuation Measurements Reveal Different Properties of Brain Tissue

Biophotonics Congress: Optics in the Life Sciences Congress 2019 (BODA,BRAIN,NTM,OMA,OMP), 2019
We explore the polarization-(in)dependent transmitted light intensity of histological brain sections. Using experimental and simulation studies, we demonstrate that it contains valuable information about nerve fiber architecture and tissue structure.
Menzel, Miriam   +4 more
openaire   +3 more sources

Direct measurement of the polarimetric parameters of a retarder with diattenuation and depolarization

Optica Latin America Optics and Photonics Conference (LAOP) 2024
A method is presented to measure the polarimetric parameters, including depolarization, for a retarder with diattenuation. The method calculates the values of the diattenuation, retardance, the axes of the sample, as well as its depolarization.
Martha Rosete-Aguilar   +2 more
exaly   +2 more sources

Characterizing Multilayer, Low Diattenuation Mirrors With a Mueller Matrix Imaging Polarimeter

Optical Interference Coatings, 2007
A multilayer, low diattenuation mirror was measured with a Muller matrix imaging polarimeter. The measured diattenuation and absolute reflectance were used to characterize the optical constants of each layer in-situ using a Levenberg-Marguardt optimization.
Paula K. Smith, Russell A. Chipman
openaire   +1 more source

Extraction of properties of individual component for the retarder-linear diattenuator-retarder system and its application

Optical Metrology and Inspection for Industrial Applications V, 2018
A method for extracting properties of individual components of a retader-linear diattenuator- retarder system is proposed. Since the evaluation performs in noncontact and nondestructive way, this method is applicable to inspect as-produced devices and optics. Example for its application to inspection of the polarizing beamsplitter is presented.
Bernard Gelloz   +3 more
openaire   +1 more source

Characterization of linear diattenuator and retarders using a two-modulator generalized ellipsometer (2-MGE)

SPIE Proceedings, 2002
The two-modulator generalized ellipsometer (2-MGE) is a spectroscopic polarization-sensitive optical instrument that is sensitive to both standard ellipsometric parameters from isotropic samples as well as cross polarization terms arising from anisotropic samples.
Gerald E. Jellison, Jr.   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy