Results 251 to 260 of about 479,874 (304)

Synchronous Islanded Operation of a Diesel Generator

IEEE Transactions on Power Systems, 2007
The amount of distributed generation connected to the distribution network is increasing. To use this resource more effectively, splitting of the distribution network, or islanding the system, for prevention of power outages is being considered by some utilities.
Best, Robert   +3 more
openaire   +2 more sources

Practical Testing of Diesel Generators

IEEE Transactions on Nuclear Science, 1985
The testing of diesel generators is a very important facet of the safe operation of nuclear power plants. Improper testing can lead to increased failures and unavailability of the engines resulting in a reduced safety factor for a nuclear plant. For a testing program to be successful it must be well planned and effectively implemented.
C. W. Angle, S. P. Meyer
openaire   +1 more source

REMEDIAL MEASURES FOR THE FOUNDATION OF A DIESEL GENERATOR

ISET Journal of Earthquake Technology, 1974
Punjab Government has installed a power house of 2.2 MW capacity at Patran, Punjab. There are two German make Diesel engine generator sets of capacity 1.1 MW each. Both the sets are founded on a combined foundation. During erection, the anchor bolts of one of the engines were painted with bitumen and as soon as the engine was started the anchor bolts ...
A. S. ARYA, M. K. GUPTA
openaire   +1 more source

Special Diesel Generator Monitoring

SAE Technical Paper Series, 1994
<div class="htmlview paragraph">As the on-site source for emergency AC power, emergency diesel generators at nuclear power plants receive a great deal of attention from plant staff as well as industry regulators. Peach Bottom Atomic Power Station recently undertook the task of reconstituting the design basis and improving the plant licensing ...
Jeffrey E. Hart, Kenneth A. Kuhar
openaire   +1 more source

Diesel-generator program manual

1996
This program provides comprehensive dynamic analysis of a diesel engine driven three phase synchronous generator connected through a delta/star (Dy11) transformer to a load busbar, to which an induction motor can be connected. Full electrical and mechanical dynamic behaviour are simulated by the use of validated models under a variety of user-selected ...
M.-J. Chen, M. Buamud, D. M. Grant
openaire   +1 more source

Analysis of a diesel generator crankshaft failure

Engineering Failure Analysis, 2009
Abstract This paper analyses a catastrophic crankshaft failure of a four-stroke 18 V diesel engine of a power plant for electrical generation when running at a nominal speed of 1500 rpm. The rated power of the engine was 1.5 MW, and before failure it had accumulated 20,000 h in service operating mainly at full load.
F. Jiménez Espadafor   +2 more
openaire   +1 more source

Analysis of a diesel generator cylinder failure

Engineering Failure Analysis, 2010
Abstract This paper analyses a catastrophic cylinder failure of a four stroke 14 V diesel engine of an electrical power plant when running to nominal speed of 600 rpm. The rated power of the engine was 7.5 MW and before failure had accumulated 80,000 h in service operating mainly at full load.
F. Jiménez Espadafor   +3 more
openaire   +1 more source

Motor starting on diesel generators

Electronics and Power, 1977
When a standby generator set is called on to take over the mains supply, it will probably have to restart motors that have decelerated or stopped during the 10-15 s the standby set takes to run up. But standby sets have higher impedances than the mains, so how do you decide on an economically sized generator, of standard build, compatible with an ...
openaire   +1 more source