Results 171 to 180 of about 25,441 (258)

Cardiac remodelling in type 2 diabetes: Pathophysiological mechanisms and opportunities for multiscale computational modelling and simulation

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Overview of multiscale cardiac remodelling in type 2 diabetes and how to model and simulate these changes using a human‐based, multiscale computational framework. Cardiac remodelling in type 2 diabetes occurs at ionic channel, protein, cellular, tissue and whole‐organ level, affecting the electrophysiological function, mechanical
Ambre Bertrand   +2 more
wiley   +1 more source

Computational analysis to assess hemodynamic forces in descending thoracic aortic aneurysms

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Left: Pre‐processing. First, we perform the segmentation of the Computer Tomography angiorgraphy (angio‐CT) scans of a healthy patient, obtaining the surface of a healthy thoracic aorta with a Type III aortic arch. Then, we build nine ideal configurations with Descending Thoracic Aortic Aneurysm (DTAA), varying the aortic arch ...
Francesca Duca   +7 more
wiley   +1 more source

Unveiling sex dimorphism in the healthy cardiac anatomy: Fundamental differences between male and female heart shapes

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend We present a shape modelling‐based morphological analysis of sex differences in cardiac anatomy. We conduct our analysis on 456 healthy subjects from the UK Biobank (227M/229F) to uncover sex‐based differences in healthy cardiac morphology.
Beatrice Moscoloni   +4 more
wiley   +1 more source

Panoramic voltage‐sensitive optical mapping of contracting hearts using cooperative multiview motion tracking with 12 cameras

open access: yesThe Journal of Physiology, EarlyView.
Abstact figure legend A panoramic 3D optical mapping system was developed, enabling imaging of action potential waves across the entire strongly deforming ventricular surface of beating isolated hearts. The system comprises 12 high‐speed cameras and a soccerball‐shaped imaging chamber with 48 light‐emitting diodes (LEDs).
Shrey Chowdhary   +5 more
wiley   +1 more source

Improved Myocardial Sodium Quantification at 7 T Using Interleaved 23Na/1H pTx MRI With Motion and Anatomy‐Based B1 Correction

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 1, Page 173-190, July 2026.
ABSTRACT Purpose To improve accuracy and repeatability of myocardial 23Na quantification in cardiac MRI at 7 T by combining retrospective respiratory and cardiac motion correction with a novel anatomy‐based B1 bias field correction. Methods In this study, a dual‐nuclear interleaved 23Na/1H MRI sequence at 7 T was applied.
Laurent Ruck   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy