Results 241 to 250 of about 3,503,812 (286)
Some of the next articles are maybe not open access.
Investigation of a hybrid system of nocturnal radiative cooling and direct evaporative cooling
Building and Environment, 2010In this paper, the results of a study on a hybrid system of nocturnal radiative cooling, cooling coil, and direct evaporative cooling in Tehran have been discussed. During a night, the nocturnal radiative cooling provides required chilled water for a cooling coil unit. The cold water is stored in a storage tank.
Ghassem Heidarinejad, Shahram Delfani
exaly +2 more sources
International Journal of Ambient Energy, 2016
ABSTRACTExergetic performance indicators (EPIs) of a direct evaporative cooling system (DECS) with different evaporative cooling pads (ECPs) are presented. The objective is to determine the performance and exergetic sustainability indicators of three ECPs (wood charcoal, shredded foam latex and jute fibre).
M. C. Ndukwu +3 more
openaire +1 more source
ABSTRACTExergetic performance indicators (EPIs) of a direct evaporative cooling system (DECS) with different evaporative cooling pads (ECPs) are presented. The objective is to determine the performance and exergetic sustainability indicators of three ECPs (wood charcoal, shredded foam latex and jute fibre).
M. C. Ndukwu +3 more
openaire +1 more source
Direct and Indirect Evaporative Cooling Strategies: An Analysis
Journal of Advanced Research in Mechanical Engineering and Technology, 2021Evaporative cooling can be understood as natural response of human body to effective climate control. It is the similar to the cooling principle that human body practices when moisture/ sweat vaporizes and cools off the skin. Needing less energy input, evaporative cooling is perfectly fit for uses in which decreasing high temperatures as well as energy
openaire +1 more source
Experimental study on direct evaporative cooling for free cooling of data centers
EnergyRui-Yong Mao, Zujing Zhang
exaly +2 more sources
The influence of chilled water on the performance of direct evaporative cooling
Energy and Buildings, 2017Abstract In this paper, the performance of direct evaporative air cooling (DEC) was investigated with chilled water. This may increase the performance of DEC, especially in humid weather, as the air wet-bulb temperature reduces during the cooling process.
Alaa Ruhma Al-Badri, Ahmed A.Y. Al-Waaly
openaire +1 more source
Research on the Direct Evaporative Cooling Air Conditioner
Applied Mechanics and Materials, 2013t focuses on the test and analysis of running conditions for the air conditioner and the functional segments at all levels in this paper, backed by the direct evaporative cooling air conditioning units experiment table. Analyze the influence of inlet air dry ball temperature and relative humidity to air conditioner cooling capacity and cooling ...
openaire +1 more source
Theory of Direct Evaporative Cooling
1986The theory of direct evaporative cooling owes much to Dr. Willis H. Carrier. His theory of adiabatic saturation and the standard psychrometric chart are its roots. One must know them to understand the operation of evaporative coolers.
openaire +1 more source
Assessment of utilisation potential of direct evaporative cooling for India
International Journal of Ambient Energy, 2006SYNOPSIS Hourly ambient temperature and humidity of 60 major cities of India were analysed to assess the utilisation potential of direct evaporative cooling for comfort conditioning. The hours with ambient wet-bulb temperature below 25°C, and tropical summer index above 25°C were considered as potential hours which can utilise direct evaporative ...
D. A. Hindoliya, S. C. Mullick
openaire +1 more source
Experimental investigation on the application of cold-mist direct evaporative cooling in data centers [PDF]
The rapid development of the internet era has driven the construction of numerous data centers worldwide. In hot climate, data centers consume significant energy for cooling. Cold-mist direct evaporative cooling offers a natural cooling solution that can
Rui-Yong Mao, Xing Liang, Hongwei Wu
exaly +2 more sources
Correlation of Direct Evaporative Cooling Efficiency With Media Porosity
Volume 5: Energy Systems Analysis, Thermodynamics and Sustainability; NanoEngineering for Energy; Engineering to Address Climate Change, Parts A and B, 2010. Energy consumption of HVAC&R could be reduced by integrating evaporative cooling device into air conditioning systems. Direct Evaporative Cooling (DEC) are suited for climates where the air is hot and humidity is low. In DEC, heat is absorbed whenever water is evaporated and converted to water vapor. By passing through or around a wetted surface,
James Walker +3 more
openaire +1 more source

