Results 121 to 130 of about 11,068 (262)
ABSTRACT A right‐sided aortic arch, a congenital anomaly of the aortic arch, was initially described by Fioratti and Aglietti in 1963. This condition, associated with formation of a vascular ring, can constrict mediastinal organs such as the trachea and esophagus.
Md. Deluwar Hussen +5 more
wiley +1 more source
ABSTRACT We present a case of a giant left supraclinoid ICA dissecting pseudoaneurysm managed successfully with flow diversion and adjunctive coiling, highlighting radiological findings and clinical outcome. Endovascular intervention provides a minimally invasive and durable solution with good clinical and radiological outcomes.
M. Kodeeswaran +8 more
wiley +1 more source
Experiência inicial com a utilização de sensor de pressão no tratamento endovascular de aneurismas de tórax. [PDF]
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina. Curso de Medicina.
Scur, Carlos Arthur Coelho
core
Ruptured Isolated Dissecting Aneurysm of the Posterior Inferior Cerebellar Artery Treated with Endovascular Coil Embolization: A Case Report [PDF]
Although intracranial dissecting aneurysms frequently occur in the vertebral artery, isolated dissecting aneurysm in the posterior inferior cerebellar artery are rare.
ハヤシ ヤスヒコ +9 more
core +1 more source
MIR503HG was downregulated in sepsis and sepsis‐induced cardiac dysfunction (SICD) and served as a diagnostic biomarker. Overexpression of MIR503HG attenuated myocardial injury and systemic inflammation in a septic rat model. Mechanistically, MIR503HG acted as a ceRNA by sponging miR‐497‐5p to upregulate BDNF, revealing a protective MIR503HG/miR‐497‐5p/
Pingping Qi +5 more
wiley +1 more source
DISSEKAN AORT ANEVRİZMASINA BAĞLI AKUT RENAL YETMEZLİK
Dissecting aneurysm should be thought in differential diagnosis of acute renal failure which developed in the patients with hypertension.
F. TÜRKMEN +4 more
doaj
Early Outcomes of Real‐World Aortic Valve Replacement With RESILIA Tissue in the Chinese Population
In this real‐world study of 250 Chinese patients scheduled for elective aortic valve replacement, the INSPIRIS RESILIA aortic valve demonstrated favorable 1‐year safety, with a 98.0% rate of freedom from all‐cause mortality and no observed structural valve deterioration, alongside stable hemodynamic performance.
Haitao Xu +4 more
wiley +1 more source
Dissecting vertebral artery (VA) aneurysms are difficult to obliterate when the parent artery cannot be safely occluded. In this video, we demonstrate a combined microsurgical and endovascular treatment technique for a ruptured, dissecting VA aneurysm ...
Liu, Kenneth C +9 more
core +1 more source

