Comparison of dissolved gas-in-oil analysis methods using a dissolved gas-in-oil standard

IEEE Electrical Insulation Magazine, 2011
Dissolved gas analysis (DGA) is routinely used to determine the concentrations of gases dissolved in the insulating oil of transformers. These concentrations are used to investigate and diagnose electrical or thermal faults [1]. Such faults cause the transformer oil, pressboard, and other insulating materials to de compose and generate gases, some of ...
Daniel Martin, Jaury Wijaya
exaly   +5 more sources

Analysis of Gas-Cap or Dissolved-Gas Drive Reservoirs

Society of Petroleum Engineers Journal, 1961
Abstract A numerical method of solving the partial differential equations which describe the one-dimensional displacement of oil by gas has been presented. Possible extension of the method to treat multidimensional flow is discussed, and the limitations of this extension are indicated.
H.L. Stone, A.O. Garder
openaire   +1 more source

Dissolved Gas Analysis (DGA)

2019
The collection and analysis of gases in an oil-insulated transformer were discussed as early as 1928 [1]. One of the signs of fault diagnosis in a transformer is the rapid growth of gases during a failure of an oil-filled transformer. It should be noted that these gases are dissolved in the oil. As a result, some faults could be identified by analyzing
Behrooz Vahidi, Ashkan Teymouri
openaire   +1 more source

Rapid dissolved gas analysis by means of electrochemical gas sensors

Proceedings of 2002 IEEE 14th International Conference on Dielectric Liquids. ICDL 2002 (Cat. No.02CH37319), 2003
Rapid, introductory analysis of gases dissolved in insulating oil (DGA) carried out in the field can help in effective screening of faulty transformers as well as minimising number of classical laboratory chromatographic DGA tests. It is also crucial for shortening a time gap between oil sampling and its analysis.
P. Zylka, B. Mazurek
openaire   +1 more source

Dealing with Uncertainty for Dissolved Gas Analysis

2011
This chapter presents three approaches to tackling uncertainties occurring in transformer condition assessment, including the ER approach, the hybrid FL and ER approach and the BN approach. Firstly, the methodology of transferring a transformer condition assessment problem into an MADM solution under an ER framework is presented.
W. H. Tang, Q. H. Wu
openaire   +1 more source

Dissolved-Gas Analysis for Nitrogen-Blanketed Transformers

2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA), 2020
Nitrogen-blanketed transformers gradually flush out oxygen and fault gas in the course of temperature-driven headspace pressure regulation. Consequently it is possible in many such transformers for intermittent or moderate fault gas production to go unrecognized if fixed limits are used to detect abnormal gassing.
James J. Dukarm, Zachary H. Draper
openaire   +1 more source

Dissolved gas analysis using evidential reasoning

IEE Proceedings - Science, Measurement and Technology, 2005
A novel approach to the analysis and handling of dissolved gas analysis (DGA) data from several traditional methods, namely Roger's Ratio Method, Dornenburg's Ratio Method and the Key Gas Method, is presented. Ideas taken from fuzzy set theory are applied to 'soften' the fault decision boundaries employed by each of the three methods.
K. Spurgeon   +4 more
openaire   +1 more source

Dissolved gas analysis using expert system

Student Conference on Research and Development, 2003
This project is to study a dissolved gas analysis of transformer oil using an expert system. A prototype of an expert system based on the dissolved gas analysis techniques for diagnosis of a suspected transformer faults and the appropriate maintenance actions to be taken.
M. Binti Ahmad, Z. bin Yaacob
openaire   +1 more source

Advances in data mining for dissolved gas analysis

Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075), 2002
This paper reports NGC's continued application and refinement of a data mining technique based on the Kohonen neural network. The technique has been applied to NGC's database of transformer dissolved gas-in-oil analysis (DGA) measurements for high voltage transformers.
D.G. Esp, A.J. McGrail
openaire   +1 more source

Dissolved Gas Analysis methods for distribution transformers

2016 13th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON), 2016
This paper proposes a program development for evaluating a condition of insulating oil of distribution transformer from Dissolved Gas Analysis (DGA) sampling data. The DGA methods such as Key Gas method, Total Dissolved Combustible Gas (TDCG), Dornenburg Ratio method, Rogers Ratio method and Duval Triangle method are applied to assess actual condition ...
Ekkarach Wannapring   +2 more
openaire   +1 more source