Results 11 to 20 of about 27,339 (259)
Performance of distance relays in presence of IPFC [PDF]
In this paper, the analytical and simulation results of the application of distance relay for the protection of transmission line incorporating Inter-line Power Flow Controller (IPFC) are presented. Firstly a detailed model of the IPFC and its control is proposed and then it is integrated into the 8-bus transmission system for the purposes of ...
Mojtaba Pouyan +2 more
openaire +2 more sources
Transmission lines are an important part of a power system. Transmission lines have high power transmission capacity and they are prone to faults of larger magnitudes. Various faults occur in transmission lines. Therefore, protection relays are necessary
win win tun, Ohn Zin Lin, Han Su Yin
doaj +1 more source
Experimental Investigation of Optimal Relay Position for Magneto-Inductive Wireless Sensor Networks
Magneto-inductive (MI) waveguide technology is often proposed to increase the MI communication distance without adding significant cost and power consumption to the wireless sensor network.
Gang Qiao +3 more
doaj +1 more source
This paper analyzes the outage probability (OP) and the average symbol error rate (SER) of decode-and-forward (DF) relaying. The paper derives closed-form expressions for the OP and the average SER with optimum combining (OC) considering fast-fading ...
Kyuhyuk Chung
doaj +1 more source
This paper investigates a power swing effect on a distance protection relay performance installed on (HV/EHV) transmission line as well as power system stability.
Ahmad A. Al-Badrany
doaj +1 more source
Simulation of Distance Relay for Load Encroachment Alleviation with Agent Based Supervision of Zone3
Cascaded tripping of power lines due to mal-operation of zone-3 distance relays has been one of the main causes of many previous blackouts worldwide. Encroachment of load into zone-3 characteristics during stressed system operation conditions is a basic ...
Mohamed Badr +2 more
doaj +1 more source
A New Model of Numerical MHO Distance Relay Associated with Power Swing Detector
In conventional transmission line protection, a distance relay is used to provide the primary as well as backup protection. The voltage and current phasors measurement needed by the distance relay for determining the impedance may be affected by the ...
Ayache MATI +2 more
doaj +1 more source
Relay Node Placement Based on Optimal Transmission Distance in Two-Tiered Sensor Network
With the gradual expansion of the application field in wireless sensor networks, the problems of the energy consumption has received more and more attention.
Mao Li, Feng Jiang
doaj +1 more source
STATCOM Impact on Distance Relay Performance
Flexible AC Transmission System devices provide for better utilization of already existing transmission systems as well as newly installed and upgraded systems.
Qais M. Alias
doaj +1 more source
Relay-assisted wireless energy harvesting for multihop clustered IoT network
In large-scale networks such as the Internet of Things (IoT), devices seek multihop communication for long-distance communications, which considerably impacts their power exhaustion.
B. Pavani +2 more
doaj +1 more source