Results 201 to 210 of about 30,280 (277)

Influence of the post‐processing protocol on a biocompatible 3D‐printed resin

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aimed to evaluate the cytotoxicity of a biocompatible 3D‐printed resin material for occlusal devices after post‐processing with two different high‐intensity UV‐polymerization devices and two rinsing solvents, in the presence of human gingival fibroblasts (HGFs).
Sergio López‐García   +4 more
wiley   +1 more source

Assessing the influence of titanium dioxide nanotubes incorporation on thermal and thermomechanical characteristics of 3D‐printed denture base resin

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aims to evaluate the effects of adding titanium dioxide (TiO2) nanotubes (NTs) to three‐dimensional (3D) printed denture base resin on the thermal and thermomechanical properties, which have high clinical relevance. Materials and Methods TiO2 NTs with dimensions of 30–70 nm in diameter and 2–4 µm in length were added to the ...
Zaid Basil Al‐enbary   +2 more
wiley   +1 more source

Assessment of fit accuracy and retentive strength of additively manufactured zirconia crowns luted to Ti‐base abutments with different resin cements: An in vitro study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study investigated the influence of cement gap size on the marginal and internal fit, and cement gap size and type on retention of additively manufactured zirconia (AM‐Z) crowns on titanium bases (Ti‐base). Materials and Methods A total of 135 zirconia crowns were designed with three different cement gap sizes: 20 µm, 30 µm, and ...
Rafat Sasany   +2 more
wiley   +1 more source

Impact of monomer contamination of isopropanol during post‐rinsing on the accuracy of dental models fabricated by vat photopolymerization

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose The aim of this study was to investigate the impact of an increasing level of monomer contamination of isopropanol (isopropyl alcohol [IPA]) during post‐rinsing on the dimensional stability of test samples produced by vat photopolymerization.
Florian Flierl   +5 more
wiley   +1 more source

Effect of material, prosthesis height, and aging on the fracture strength of additively and subtractively manufactured implant‐supported cantilevered prostheses

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant‐supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.
Mustafa Borga Dönmez   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy