Results 171 to 180 of about 4,259 (259)

Analog Weight Update Rule in Ferroelectric Hafnia, Using picoJoule Programming Pulses

open access: yesAdvanced Electronic Materials, EarlyView.
Resistive, ferroelectric synaptic weights based on BEOL‐compatible hafnia/zirconia nanolaminates are fabricated. Lateral downscaling the devices below 10 µm2 enables 20 ns programming with electrical pulses, dissipating ≤ 3 pJ. Experimental results show that final conductance state is set by pulse amplitude, and is largely independent of the initial ...
Alexandre Baigol   +7 more
wiley   +1 more source

Towards Real‐Time Monitoring of Soft Robotic Systems in Endoscopic Application With Ultra‐Flexible Organic Transistor‐Based Strain Sensors

open access: yesAdvanced Electronic Materials, EarlyView.
The integration of ultra‐flexible, all‐organic, field‐effect transistor‐based strain sensors to soft structures is reported for the development of sensorized soft robots. The envisaged application is the development of next‐generation, controllable, and observable soft robotic catheters for endoscopic applications, such as drug delivery. Mechanical and
Usama Mahmood   +5 more
wiley   +1 more source

Large Anomalous Nernst Effect in Disordered CoPt Thin Films for Planar Thermoelectric Sensing

open access: yesAdvanced Electronic Materials, EarlyView.
Disordered CoPt thin films exhibit a large anomalous Nernst effect with strong dependence on Pt concentration. The transverse thermoelectric response reaches 3.22 µV K−1 near equiatomic composition and an ANE sensitivity of 0.3 µm A−1. The results reveal that composition‐controlled microstructure in sputtered CoPt alloys provides an effective route for
Mojtaba Mohammadi   +2 more
wiley   +1 more source

Self‐Adhesive Conductive Elastomers for Gel‐Free Biopotential Recording

open access: yesAdvanced Electronic Materials, EarlyView.
σPOMaC, a self‐adhesive conductive citrate elastomer incorporating PEDOT:PSS and DBSA, enables gel‐free biopotential electrodes with stable conductivity and intrinsic skin adhesion. The composite exhibits low resistivity (∼ 0.02 Ω·cm), robust electrical performance during repeated use, and reliable on‐body ECG acquisition comparable to Ag/AgCl ...
Kirstie M. K. Queener   +7 more
wiley   +1 more source

Degradation Pathways of Silicon‐Based Anodes in Lithium‐Ion Batteries

open access: yesAdvanced Energy Materials, EarlyView.
Silicon‐based anodes undergo degradation through five primary pathways: (1) mechanical and structural deterioration of the active material, (2) loss of electrode integrity and electrical contact, (3) mechanical instability of the solid electrolyte interphase (SEI), characterized by repetitive fracture and deformation, (4) chemical instability of the ...
Yoon Jeong Choi   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy