Results 51 to 60 of about 712,543 (297)

Microstructural Evolution and Vacancy Defect Formation in Mn–Mo–Ni RPV Steel Under Low Cycle Fatigue: Insights From EBSD and PALS

open access: yesAdvanced Engineering Materials, EarlyView.
Low‐cycle fatigue damage in Mn–Mo–Ni reactor pressure vessel steel is examined using a combined electron backscatter diffraction and positron annihilation lifetime spectroscopy approach. The study correlates texture evolution, dislocation substructure development, and vacancy‐type defect formation across uniform, necked, and fracture regions, providing
Apu Sarkar   +2 more
wiley   +1 more source

Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of a silane‐doped argon atmosphere on the chemical composition and temperature of a thermal nontransferring argon plasma is investigated using optical emission spectroscopy. As a result of the high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule, even a silane addition of 0.01 vol ...
Lena Kreie   +4 more
wiley   +1 more source

Sensitivity of hemodynamic parameters obtained by conventional duplex scanner in the evaluation of extracranial carotid disease severity [PDF]

open access: yesVojnosanitetski Pregled, 2003
Progresson of extracranial carotid disease is considered to be significant independent predictor in the evaluation of individual cerebrovascular prognosis.
Aranđelović-Minić Gordana
doaj   +1 more source

Poly(lactic‐co‐glycolic acid) Nanoparticles for IL‐12 Self‐Amplifying RNA Delivery in Glioblastoma Models

open access: yesAdvanced Functional Materials, EarlyView.
xxxx. ABSTRACT Glioblastoma (GBM) remains one of the most lethal brain cancers, with median survival rarely exceeding 15 months after diagnosis. Interleukin‐12 (IL‐12) is a potent immunostimulatory cytokine capable of reshaping the tumor microenvironment (TME), yet its clinical translation is hindered by systemic toxicity and short half‐life. RNA‐based
Fatima Hameedat   +11 more
wiley   +1 more source

Doppler broadening integrals [PDF]

open access: yesMathematics of Computation, 1966
These results may be obtained by introducing the representation (1 + y2)-V= fO ecos yz dz, or by solving the coupled differential equations dlo/dx 2v(1I xlo), dl1/dx = 2v(7r IoxI), or by simply making appropriate changes of variable in some tabulated integrals [2].
Wood, Van E.   +2 more
openaire   +2 more sources

Doppler lidar results from the San Gorgonio Pass experiments [PDF]

open access: yes, 1984
During FY-84, the Doppler Lidar data from the San Gorgonio Pass experiments were analyzed, evaluated, and interpreted with regard to signal strength, signal width, magnitude and direction of velocity component and a goodness parameter associated with the
Cliff, W. C.   +2 more
core   +1 more source

Measurement-based analysis of Doppler characteristics for ultra-wideband radio channels in an office environment [PDF]

open access: yes, 2014
In this work, an analysis of the Doppler characteristics for Ultra-Wideband indoor communication is presented. Channel sounding measurements ranging from 3.1 to 10.6 GHz were performed over the course of several days in an occupied office environment ...
Hanssens, Brecht   +4 more
core   +1 more source

From Clinic to Computation: Multiscale Bioengineering Strategies for Durable Biological Aortic Valve Replacements

open access: yesAdvanced Functional Materials, EarlyView.
Bioprosthetic aortic valves have revolutionized the treatment of aortic stenosis, but their durability is limited by structural valve deterioration (SVD). This review focuses on the pericardial tissue at the heart of these valves, examining how its mechanical properties and calcification drive fatigue and failure.
Gabriele Greco   +7 more
wiley   +1 more source

MRI Visibility and MR–DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device: A Preclinical Study

open access: yesBrain Sciences
Background/Objectives: This GLP (Good laboratory practice) study evaluates the MRI compatibility and occlusion performance of the Nuvascular Harbor intrasaccular device for the treatment of bifurcation and sidewall aneurysms in a rabbit aneurysm model ...
Gökce Hatipoglu Majernik   +7 more
doaj   +1 more source

Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling

open access: yesAdvanced Healthcare Materials, EarlyView.
Emerging advances in three‐dimensional bioprinting and computational modeling are reshaping cardiovascular (CV) research by enabling more realistic, patient‐specific tissue platforms. This review surveys cutting‐edge approaches that merge biomimetic CV constructs with computational simulations to overcome the limitations of traditional models, improve ...
Tanmay Mukherjee   +7 more
wiley   +1 more source