Comparison of multidetector-row computed tomography and duplex Doppler ultrasonography in detecting atherosclerotic carotid plaques complicated with intraplaque hemorrhage [Usporedba višeslojne kompjuterizirane tomografije i duplex Doppler ultrazvuka u otkrivanju aterosklerotskih karotidnih plakova kompliciranih krvarenjem u plak ] [PDF]
This study compared sensitivity and specificity of multidetector-row computed tomography and duplex Doppler ultrasonography in detecting atherosclerotic carotid plaques complicated with intraplaque hemorrhage.
Ajduk, Marko +8 more
core
Structural and inflammatory sonographic findings in erosive and non-erosive osteoarthritis of the interphalangeal finger joints [PDF]
Objective The objectives were: (1) to determine if ultrasound (US) can detect more erosions in erosive osteoarthritis (EOA) of the interphalangeal (IP) joints than conventional radiography (CR); and (2) to explore the frequency of structural and ...
Carron, Philippe +2 more
core +2 more sources
Neurovascular Contacts in the Pathophysiology of Neuralgic Amyotrophy: An Observational Study
ABSTRACT Objective Neuralgic amyotrophy (NA) is a prevalent, monophasic, multifocal immune‐mediated neuropathy. A distinctive characteristic of the disease is the occurrence of nerve or fascicle constrictions and torsions (NA‐associated focal nerve lesions, NAFL). The pathophysiology underlying this phenomenon remains to be fully elucidated.
Johannes Fabian Holle +4 more
wiley +1 more source
Contexto: A arteriografia com contraste (AC) tem sido o exame tradicional de avaliação de pacientes com suspeita de doença oclusiva aorto-ilíaca (DOAI).
Ricardo Cesar Rocha Moreira
doaj +1 more source
Objective We aimed to validate the Pediatric Arthritis Ultrasound Scoring System (PAUSS) for upper extremity joints in children with juvenile idiopathic arthritis (JIA). Methods Children with JIA were evaluated for elbow, wrist, or finger arthritis by clinical examination (CE) and musculoskeletal ultrasound (MSUS) with images scored according to the ...
Patricia Vega‐Fernandez +12 more
wiley +1 more source
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
In vivo real-time epifluorescence imaging of mouse hindlimb vasculatures in the second near-infrared region (NIR-II, 1.1~1.4 microns) is performed using single-walled carbon nanotubes (SWNTs) as fluorophores.
Cooke, John P. +7 more
core +1 more source
Systemic sclerosis (SSc) is a rare autoimmune disease defined by immune dysregulation, vasculopathy, and progressive fibrosis of the skin and internal organs. Despite advances in care, major complications such as interstitial lung disease (ILD) and myocardial involvement remain the leading causes of morbidity and mortality.
Cristiana Sieiro Santos +2 more
wiley +1 more source
Low‐cycle fatigue damage in Mn–Mo–Ni reactor pressure vessel steel is examined using a combined electron backscatter diffraction and positron annihilation lifetime spectroscopy approach. The study correlates texture evolution, dislocation substructure development, and vacancy‐type defect formation across uniform, necked, and fracture regions, providing
Apu Sarkar +2 more
wiley +1 more source
Fluorescence optical imaging for treatment monitoring in patients with early and active rheumatoid arthritis in a 1-year follow-up period [PDF]
BACKGROUND: Fluorescence optical imaging (FOI) enables visualization of inflammation in the hands in rheumatic joint diseases with currently a lack of long-term follow-up studies.
Backhaus, Marina +10 more
core +2 more sources
Bioprosthetic aortic valves have revolutionized the treatment of aortic stenosis, but their durability is limited by structural valve deterioration (SVD). This review focuses on the pericardial tissue at the heart of these valves, examining how its mechanical properties and calcification drive fatigue and failure.
Gabriele Greco +7 more
wiley +1 more source

