Interference of TiO2 in Fricke Dosimetry: Adsorption Mechanisms and Dose Measurement Challenges under Gamma Irradiation

open access: yesChemistryOpen, Volume 15, Issue 4, April 2026.
The presence of TiO2 in Fricke dosimetric systems introduces complex interferences under gamma irradiation. Adsorption of Fe2+/Fe3+ ions, coupled with radiolytic and surface‐mediated processes, alters redox equilibria and apparent absorbed dose values, highlighting critical challenges in chemical dosimetry applied to heterogeneous radiolytic ...
William Villacis   +4 more
wiley   +1 more source

Impact of the Different Announcers of Taheri Consciousness Fields on GR-200 Dosimeters

open access: diamond, 2023
Mohammad Ali Taheri   +4 more
openalex   +2 more sources

Radiation‐Crosslinked PCL–TMPTA Composites via 3D Printing: Structure–Property Relationships and Shape Memory Performance

open access: yesPolymer Engineering &Science, Volume 66, Issue 4, Page 2858-2870, April 2026.
3D printed shape memory PCL‐TMPTA through high energy gamma radiation modification. ABSTRACT Programmable materials that can reversibly transform between distinct shapes represent a promising technology for applications spanning biomedicine, robotics, and aerospace engineering. Although shape memory polymers offer promising stimuli‐responsive behavior,
Khushboo Varshney   +3 more
wiley   +1 more source

Dielectric Properties of Materials Used for Microwave-Based NOx Gas Dosimeters

open access: yesSensors
Nitrogen oxides (NOx), primarily generated from combustion processes, pose significant health and environmental risks. To improve the coordination of measures against excessive NOx emissions, it is necessary to effectively monitor ambient NOx ...
Stefanie Walter   +5 more
doaj   +1 more source

Conductometric Sensor for Soot Mass Flow Detection in Exhausts of Internal Combustion Engines

open access: yesSensors, 2015
Soot sensors are required for on-board diagnostics (OBD) of automotive diesel particulate filters (DPF) to detect filter failures. Widely used for this purpose are conductometric sensors, measuring an electrical current or resistance between two ...
Markus Feulner   +6 more
doaj   +1 more source

Mortality from cancer and non‐cancer diseases in the Lithuanian cohort of Chernobyl cleanup workers (2001–2020)

open access: yesInternational Journal of Cancer, Volume 158, Issue 6, Page 1498-1506, 15 March 2026.
What's new? Following the Chernobyl disaster, workers were recruited from formerly Soviet‐occupied areas, including Lithuania, to participate in clean‐up efforts. Radiation exposure incurred by workers during these efforts offers a unique opportunity for the study of long‐term health effects.
Rita Steponaviciene   +3 more
wiley   +1 more source

Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques

open access: yesSensors and Actuators B: Chemical, 2018
Optical absorbance and dynamic light scattering studies of Fricke xylenol orange gel dosimeters loaded with laponite were carried out with the aim to investigate possible effects of nanoparticles on the dosimetric properties and diffusion phenomena of ...
S. Gallo   +9 more
semanticscholar   +1 more source

INVESTIGATION OF DOSIMETRIC PROPERTIES OF TABLE SUGAR IRRADIATED WITH GAMMA RAYS USING EPR TECHNIQUE

open access: yesGazi Üniversitesi Fen Bilimleri Dergisi
In our study, it was observed that the EPR signals of table sugar irradiated with gamma rays at 3 kGy, 5 kGy, 10 kGy increased in proportion to the increasing dose.
Gül Bayramiye Özmen, Eren Şahiner
doaj   +1 more source

Wrist dosimeter in nuclear medicine – An alternative for the ring dosimeter?

open access: yesPhysica Medica, 2018
Individual dosimetry is undoubtedly one of the best methods of assessing the exposure of personnel to ionizing radiation, however in case of nuclear medicine, the method applied to measure the dose does not always present a picture of the worker's actual exposure.
Wrzesień, Małgorzata, Olszewski, Jerzy
openaire   +2 more sources

Embedded structure fiber-optic radiation dosimeter for radiotherapy applications.

open access: yesOptics Express, 2016
An investigation into a novel in-vivo PMMA (polymethyl methacrylate) plastic fiber-optic dosimeter for monitoring low doses of ionizing radiotherapy radiation in real time and for integrating measurements is presented.