Results 41 to 50 of about 4,014 (147)

A Gamma Alarm system for radiation protection

open access: yesNucleus, 2017
This paper describes the development of an instrument for radiological monitoring, identified as Gamma Alarm (GAMAL01). The instrument monitors the increment of radiation count rate and produces an alarm signal, when the count rate becomes superior to a ...
René Toledo Acosta   +5 more
doaj  

Implementación de un sistema económico para vigilancia radiológica para el Personal Ocupacionalmente Expuesto en Servicios de Medicina Nuclear [PDF]

open access: yes, 2017
The nature of the routine activities carried on in nuclear medicine services, where several not sealed radioactive sources are used, the occupational personal exposed (POE, to ionization radiation) is exposed to both, internal and external radioactive ...
VALLE ROJAS, JOSE, VALLE ROJAS, JOSE
core  

Application of an Elekta Precise lineal accelerator model based on Monte Carlo to evaluate the solid state detectors response

open access: yesNucleus, 2015
The evaluation of the solid state detectors response based on a Monte Carlo model of an Elekta Precise lineal accelerator, was done in this work for the beam energies of 6 y 15 MV. Simulations were performed using the EGSnrc code.
Haydee M. Linares Rosales   +2 more
doaj  

Ainda é preciso falar sobre o enunciado 231 da Súmula do Superior Tribunal de Justiça?

open access: yesBoletim IBCCRIM, 2020
O artigo é uma crítica ao enunciado 231 da Súmula do Superior Tribunal de Justiça a partir da operacionalização da dosimetria da pena formulada por Nelson Hungria e adotada pelo Código Penal, bem ainda da legalidade penal, notadamente sob o seu viés da ...
Victor Matheus Bevilaqua
doaj  

Actualización en legislación sobre protección radiológica dental [PDF]

open access: yes, 2018
Objetivos: Revisión de las bases físicas en las que se fundamentan las radiaciones ionizantes, los posibles efectos biológicos tanto a nivel sistémico como local en la cavidad oral y revisión actual de la legislación sobre Instalaciones de ...
Sousa Jiménez, Manuel Jesús
core  

Quality control in podiatry radiology: proposed criteria for image quality and reference dose [PDF]

open access: yes, 2011
La transposición a la legislación española de la normativa comunitaria relativa a la calidad en actos radiológicos obliga a los titulares de instalaciones de radiodiagnóstico a seguir un programa de garantía de calidad.
Becerro de Bengoa, Ricardo   +2 more
core   +2 more sources

Cálculo de Dosimetría Mediante Elementos Finitos con Adaptabilidad Automática hp en Tres Dimensiones [PDF]

open access: yes, 2010
In this communication the effect of the electromagnetic radiation on in vitro cell cultures is analyzed using a self-adaptive hp-Finite Element Method (hp-FEM) in three dimensions.
García Castillo, Luis Emilio   +3 more
core  

Propiedades termoluminiscentes de una albita de minas Geraes (Brasil)

open access: yesBoletín de la Sociedad Española de Cerámica y Vidrio, 2004
Albite sodium feldspar is studied by thermoluminescent methods using the blue region of the spectra (circa 400nm) and the possible uses as a dosimeter are explored.
García-Guinea, J.   +5 more
doaj  

Medición de la Radiación Ambiental en el Centro Nuclear "Racso" Usando Dosimetría Termoluminiscente

open access: yesRevista de Investigación de Física, 1998
La dosimetríatermoluminiscente ha sifo utilizada para medir la radiación ambiental debida a la radiación gamma en la vecindad den Centro Nuclear "RACSO".
T. Benavente, E. Celedonio
doaj   +1 more source

Manual de entrenamiento sistematizado para el personal operativo de una planta de producción de comestibles [PDF]

open access: yes, 2008
El artículo contiene los resultados del estudio de necesidades de entrenamiento de los operarios en una empresa productora de alimentos, cuyo objetivo fue la consolidación de un instructivo para la formación y mejoramiento del desempeño del personal ...
Marín del Río, José Alejandro   +2 more
core   +3 more sources

Home - About - Disclaimer - Privacy