Viability of Non-Coplanar VMAT for Liver SBRT as Compared to Coplanar VMAT and Beam Orientation Optimized 4π IMRT. [PDF]
PurposeThe 4π static non-coplanar radiotherapy delivery technique has demonstrated better normal tissue sparing and dose conformity than the clinically used volumetric modulated arc therapy (VMAT).
Cao, Minsong +7 more
core +1 more source
Dynamic multileaf collimator (DMLC) and static multileaf collimator (SMLC), along with three-dimensional treatment planning system (3-D TPS), open the possibility of tissue compensation.
Kinhikar Rajesh +4 more
doaj
A seed specific dose kernel method for low-energy brachytherapy dosimetry. [PDF]
We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom ...
Agazaryan, Nzhde +2 more
core +1 more source
Optimizing a Quality Control Procedure for Intensity Modulated Radiation Therapy
A patient-specific quality assurance (QA) program to carry out the dosimetric verification of the intensity modulated radiation therapy (IMRT) was optimized at the Department of Radiotherapy at the Institute of Oncology and Radiobiology, belonging to ...
Eduardo F. Larrinaga Cortina +2 more
doaj
Monte Carlo Simulation of a 6 MV X-Ray Beam for Open and Wedge Radiation Fields, Using GATE Code
The aim of this study is to provide a control software system, based on Monte Carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fields, using a Monte Carlo method.
Mohammad-Taghi Bahreyni-Toosi +4 more
doaj
Verification of Acuros XB dose algorithm using 3D printed low‐density phantoms for clinical photon beams [PDF]
Khan, Rao +4 more
core +2 more sources
Purpose: Spot-scanning hadron arc radiation therapy (SHArc) is a novel delivery technique for ion beams with potentially improved dose conformity and dose-averaged linear energy transfer (LETd) redistribution. The first dosimetric validation and in vitro
Thomas Tessonnier, PhD +11 more
doaj +1 more source
Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer. [PDF]
Jeong Y +4 more
europepmc +1 more source
Hydrogel spacer distribution within the perirectal space in patients undergoing radiotherapy for prostate cancer: Impact of spacer symmetry on rectal dose reduction and the clinical consequences of hydrogel infiltration into the rectal wall [PDF]
Bosch, Walter +4 more
core +2 more sources
Dosimetric verification of stereotactic body radiotherapy treatment plan via ArcCHECK-3DVH system. [PDF]
Cheng S +5 more
europepmc +1 more source