Quantitative dosimetric verification of an IMRT planning and delivery system

Radiotherapy and Oncology, 1998
The accuracy of dose calculation and delivery of a commercial serial tomotherapy treatment planning and delivery system (Peacock. NOMOS Corporation) was experimentally determined.External beam fluence distributions were optimized and delivered to test treatment plan target volumes, including three with cylindrical targets with diameters ranging from 2 ...
D A, Low   +6 more
openaire   +2 more sources

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers

Physics in Medicine and Biology, 2001
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in
E, Spezi, D G, Lewis, C W, Smith
openaire   +2 more sources

Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience

Radiotherapy and Oncology, 2006
In our clinic a QA program for IMRT verification, fully based on dosimetric measurements with electronic portal imaging devices (EPID), has been running for over 3 years. The program includes a pre-treatment dosimetric check of all IMRT fields. During a complete treatment simulation at the linac, a portal dose image (PDI) is acquired with the EPID for ...
Zijtveld, Mathilda   +3 more
openaire   +3 more sources

Camera based EPID dosimetric verification of radiation treatments

2018
Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.
Nazari, Vahideh   +5 more
openaire   +1 more source

[Dosimetric verification of the intensity modulated radiation therapy].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation, 2012
To research the method of dosimetric verification of the intensity modulated radiation therapy (IMRT).The IMRT treatment plans were designed by Eclipse TPS and were implemented in Varian ClinacIX LA with 6MV X-ray. The absolute point doses were measured using a PTW 0.6 cc ion chamber with UNIDOS E dosimeter and the planes dose distributions were ...
Yuhai, Zhang, Yang, Gao
openaire   +1 more source

Dosimetric verification of compensated beams using radiographic films

2009
Intracavitary application of brachytherapy sources followed by external beam radiation is common practice in radiotherapy of carcinoma of the cervix. Since brachytherapy sources deliver very high doses to the central portion of the target volume this part must be shielded while irradiate with photon beams.
Žauhar, Gordana   +4 more
openaire   +1 more source

1374 poster IMRT DOSIMETRIC VERIFICATION PROCEDURE

Radiotherapy and Oncology, 2011
S. Pellejero   +9 more
openaire   +1 more source

399 Dosimetric verification with portal imaging

Radiotherapy and Oncology, 2005
E. Whlin, B. Sorcini, S. Axelsson
openaire   +1 more source

Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

Medical physics, 2005
Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured the dosimetric accuracy and ...
Nathan L, Childress   +5 more
openaire   +1 more source