Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation [PDF]
Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs).
Micaeil Mollazadeh +4 more
doaj +1 more source
Use of radiobiological modeling in treatment plan evaluation and optimization of prostate cancer radiotherapy [PDF]
There are many tools available that are used to evaluate a radiotherapy treatment plan, such as isodose distribution charts, dose volume histograms (DVH), maximum, minimum and mean doses of the dose distributions as well as DVH point dose constraints ...
Baltas, Dimos +3 more
core +1 more source
Feasibility Study of Transit Dosimetry (TD) with an Electronic Portal Imaging Device (EPID) in volumetric arc therapy (VMAT) for head and neck cancer (HNC) [PDF]
Introduction: The progress in radiotherapy treatment modalities, such as Intensity Modulated Radiotherapy (IMRT) and Volumetric Arc Therapy (VMAT), introduces considerable complexity.
ARVIND DIUNDI +3 more
doaj +1 more source
Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations. [PDF]
Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image-based treatments that lag behind technical capabilities available for nonurgent ...
Fogh, Shannon E +4 more
core +1 more source
Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning [PDF]
BACKGROUND AND PURPOSE: To investigate the accuracy of photon dose calculations performed by the Anisotropic Analytical Algorithm, in homogeneous and inhomogeneous media and in simulated treatment plans.
Ahnesjö +25 more
core +1 more source
Dosimetric Verification in Intensity Modulated Radiation Therapy
As part of dosimetric verification for IMRT intensity modulated radiation therapy, we examined the selection of a dosimeter in accordance with the purpose of physical measurement and the process of data analysis. Because of the high dose conformation in the target volume and minimum dose in the organs at risk (OAR) in IMRT, dosimetric verification is ...
Yuichiro, Narita +7 more
openaire +3 more sources
Background To evaluate the dosimetric and biological benefits of the fixed-jaw (FJ) intensity-modulated radiation therapy (IMRT) technique for patients with T-shaped esophageal cancer.
Hua Chen +8 more
doaj +1 more source
Considerations for the verification of volumetric modulated arc therapy-planned dose distributions
Background: Volumetric modulated arc therapy (VMAT) is the standard of care for many clinical indications, but should only be considered with proper technical support and quality assurance (QA) in place.
Lourens Strauss, William Shaw
doaj +1 more source
Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy. [PDF]
Monte Carlo (MC)-based dose calculations are generally superior to analytical dose calculations (ADC) in modeling the dose distribution for proton pencil beam scanning (PBS) treatments.
Ainsley, Christopher +7 more
core +2 more sources
Developing a Verification and Training Phantom for Gynecological Brachytherapy System [PDF]
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the ...
Mahbobeh Nazarnejad +4 more
doaj +1 more source